Specifications

Modular I/O Configuration Guide98
Input Level Switches: Use the table below to set switches 1–4 to match the selected input level to 0 dBFS (full scale level).
For Example: Set 0 dBFS = +24 dB to achieve -20 dBFS = +4 dBU = 0 VU.
Technical Specifications
Analog Level
0 dBFS (full scale)
SW1 SW2 SW3 SW4
+15 dBU OFF OFF OFF OFF
+18 dBU OFF OFF OFF ON
+21 dBU OFF OFF ON OFF
+24 dBU OFF ON OFF OFF
+28 dBU ON OFF OFF OFF
To avoid damaging analog circuits, install a master sync source module in a red reserved slot before applying AC power.
Resolution 24 bit
Sample Rate 32
96 kHz
Dynamic Range
113 dB (RMS)
116 dB (A)
THD+N <0.002% @ maximum input level
Frequency Response
48 kHz: 10 Hz – 20 kHz (
0,5 dB)
96 kHz: 10 Hz – 40 kHz (
0,5 dB)
Crosstalk
>100 dB (1 kHz)
>95 dB (20 kHz)
>85dB (40 kHz)
Maximum Input Level 15
28 dBu @ 0dBFS
Input Impedance 10 k, floating balanced
Connector XLR, 1:GND, 2:+, 3: -
Backplane Connector DIN41612, 64-pin, a+b, male
Power Supply +5 VDC
Consumption ~850 mA
Dimensions 3 RU, 8 HP (2 slots)