Specifications

Chapter 2: Typical Frame Configurations 25
Control
To set up remote control for the IO95 Frame, use the FC972 Remote to configure the following parameters:
1 Set the IP Address range to 192.168.0.157~159/255.255.255.0.
2 Set the Gateway to 192.168.0.1 for configuration by console system computer.
Module CAN IDs
Set the CAN ID of each module to match the table below.
Power
The IO95 Multi-zone Frame has a maximum power capacity of 13 A @ 5 VDC. Individual module and the IO95’s total power con-
sumption are summarized in the table below.
:
See “FC972 Remote” on page 49 for details.
This frame does not contain mic preamps so IP Address range 192.168.0.150~156 is skipped.
See each module’s section in Part III to learn how to set its CAN ID.
IO95 Multi-zone Frame
Module CAN ID
MM935 0
DE911 #1 1
DE911 #2 2
DE911 #3 3
DD916 #1 4
DD916 #2 5
DD916 #3 6
DD916 #4 7
DD916 #5 8
DD916 #6 9
IO95 Multi-zone Frame Module Power Consumption
Module Quantity Power (A) Subtotal (A)
SY983
4
.30 1.20
FC972
1
.30 .30
MM935
1
.36 .36
DD915
6
1.00 6.00
DE911
3
.60 1.80
Total (A): 9.66