Specifications

Chapter 10: AES I/O and HD Modules 115
Setting BUS-EN
The output configuration is taken from the non-volatile memory.
SW1-1 ON connects the outputs to the audio busses on power up.
SW1-1 OFF disconnects the module outputs from the audio busses on power up.
Setting MASTER
If this module will be the master sync source in a IO93 or IO94 Frame, it must be placed in a red reserved slot. Select the input
to use as clock reference using the web browser interface.
SW1-2 ON sets this module as clock master for the frame.
SW1-2 OFF if this module is not clock master for the frame.
Front Panel LEDs
To avoid audio bus conflicts when installing or replacing a module and the configuration is unknown, disable the output bus
drivers by setting BUS-EN = OFF before inserting it. If all settings are done remotely and the unit fits into the frame’s bus as-
signment scheme, remove it and set BUS-EN = ON.
Green Status OK
Green Flashing Module is under FC972 Remote control
Red
Status is bad, remote reading of the status with GUI is
required. The FC972 Remote has probably issued a SNMP trap.
MASTER LED
Off The audio bus interface clock must be provided by the frame
Red DD916 is clock master for the frame