Specifications

Modular I/O Configuration Guide110
Setup/Routing Page
This page controls DD915 routing and setup parameters.
Relay Bypass
The AES I/Os provide a bypass relay for all eight channels, which may be turned off. With Relay Bypass On, the I/Os are in Relay
Bypass mode.
Relay Wait Time After Power Up
The Relay Bypass is active as long as the module has no power. If power is turned on, the module waits this amount of time before
the relays are engaged to disable Relay Bypass.
MASTER SELECT
If the module is set to MASTER mode, select one of the four AES/EBU inputs to use as the clock reference. The module must be in-
stalled in one of the frame’s red reserved slots.
Sample Rate Converter
Each AES/EBU input can be enabled/disabled for SRC.
To C8000 Bus Output Mux
The multiplex mode for audio signals routed to the audio bus can be set to 2ch or 8ch.
DD915 Web Configuration Setup/Routing page