Instruction manual
Euphonix Modular I/O Configuration Guide Product Data Sheets
64
3/7
Installation
Set SW1 (A – D) if necessary (default = off)
Set SW2 (DEV0 – 2) for an appropriate CAN frame address (default = off).
Set SW2-4 (CAN-TERM) to terminate the CAN bus if required (default = off)
Location of label switches on the C8702 module.
The default IP address label is located on the “Coldfire” chip
of the controller module and on the front panel of the module.
While the MAC address is
printed on a label here
Can Buss Termination
Can Buss Termination must be done on either the SY982 Sync or FC972
Remote. Lack of termination or double termination may result in communication
errors in the system. Typically, Can Termination is done on the FC972.
Mode Switches
Mode switch A is set to “ON” for use with Euphonix consoles. Mode switches B,
C, & D are set to “OFF”
Setting the frame ID
Set DEV0, DEV1, & DEV2 to “ON.”
FC972 Remote