Instruction manual

System 5 Digital Audio Mixing System Operation Manual Dynamic Automation
187
13.8.4 Fill Start + Fill End
1. Press Fill End then Fill Start in the center section automation panel.
Both keys should be illuminated.
2. Punch in the parameter and adjust the control to the desired level.
3. Punch out and the level at that time is written throughout the mix.
Using Fill Start and Fill End together is a useful way to set a static value all the way
through the mix.
13.8.5 Setting Fill Start and End Times
The Fill Region features, discussed in the next sections, require setting the F/Start and
F/End time fields in Automation Panel Page 1. The Fill Region key must be lit for
these times to be used.
1. From the Main Panel, press the Automation button to display Automation
Panel Page 1.
2. Enter a timecode into the locate time display using the numeric keypad on the
center section (Figure 13-13). The entire time must be entered, beginning with
frames. When the first numeric key is pressed, the display clears to enter the
new value.
A time can also be entered by recalling a Cue (see Cue Points on page 146).
3. Press Store Locate and then the F/Start key in Automation Panel Page 1 to
transfer the locate time to the F/Start field.
4. Enter the F/End time into the locate time display by repeating step 2.
5. Press Store Locate and then the F/End key in Automation Panel Page 1 to
transfer the locate time to the F/End field.
Figure 13-13 Setting times in the machine control panel
Fill
Fill
hr min
bar
sec / ft
beat
Fr/ms
Tick
locate time
Time
Display
_
+
Edit
Trim
+
Trim
-
Locate
Reg’s
78 9
Cue
Store
Current
Store
Locate
Recal
l
Delete
00:12:24:03
00:16:11:04