User`s guide

Preliminary Manual RELAY BOX - RB132/GP132 USERS GUIDE
EUPHONIX INC - RB132/GP132 p13 Wednesday, August 26
th
, 2000
MixView Software Supplement Version 3.0 Revision 2
SECTION 10 : MX464
Pulsed GPI
Switching
GPI control has been enhanced in v3.0 software through the addition of the
pulsed GPI control parameters. Each GPI relay can be set for pulsed (momentary
y) operation. Additionally , this behavior can be set to operate in either or
both fader movement directions and for selectable timing intervals (pulse
width) from 20mS - 2.54s. From the top level SmartDisplay menu, press [F3]
twice to display the GPI menu and screen:
System-wide GPI
Relay and
Speaker
mutes
MX464 GPI relays and speaker mutes are now configured ‘system-wide’
and only the assignment to faders is title-specific. The initialize (reset)
state, action state and pulse width timing of a relay or speaker mute do
not change when a title is loaded or saved.
This system-wide data is stored in the DSC’ s batter y-backed RAM and
is not dependent on the PC. Once set, these settings should never need
attention unless the lithium cell fails or the DSC module is replaced.