Specifications

Euphonix MADI Converters Operation Manual MI715/MO705 Converters Features
12
Ϯ͘ϲSynchronization
Ϯ͘ϲ.1 MI715
TheMI715’sSampleRateissetexternallybyoneoftwosourcesignalsorinternallyby
crystalsandassociatedcircuitry.TheSampleRateSourceisdeterminedautomatically
bythepresenceofsignalswhentheMI715ispoweredon.Theorderinwhichexternal
signalsaretestedforpresenceis:AES,Word,Internal.
ThedetectedsignalimmediatelybecomesthesourcefortheMI715’ssamplerate
clock.TheautosensedSampleRateSourcecanbeoverriddenusingthebuttononthe
frontpaneloftheMI715,belowtheSampleRateSourceLEDs.IfneitherAESnorWord
Clocksignalsarepresent,theMI715usesitsinternalclockderivedfromonboardvolt
agecontrolledcrystal.
ThedefaultinternalSampleRateoftheMI715is48kHz.Thisdefaultinternalratecan
beoverriddenwiththeSampleRatebuttononthefrontpaneloftheMI715(directly
belowtheSampleRateLEDs)to44.1,48or96kHz.
Ϯ͘ϲ.2 MO705
TheMO705detectsSampleRateandSampleRate SourceliketheMI715withthe
followingtwodifferences:
SincetheMO705isalwaysaslavetoanexternalSampleRateSource,thereis
nointernalSampleRatesetting.
•TheMO705canuseMADIinadditiontoAESorWordClockasaSampleRate
Source,anddetectsthepresenceofthesesignalsinthefollowingorder:AES,
Word,MADI.
Whenasignalisdetected,itimmediatelybecomesthesamplerateclockofthe
MO705.TheautosensedSampleRateSourcecanbeoverriddenwiththeSampleRate
SourcebuttononthefrontpaneloftheMO705,belowtheSampleRateSourceLEDs.