Specifications

Studio & Pilot Computers Manual Page 6 Version 1.01 ©1999 Euphonix Inc.
Digital Pilot
1) Attach the RJ45 network cable connector to the port labeled LAN1.
2) Attach the IEEE1394 cable to one of the ports marked IEEE1394. Attach the other end
of this cable to the FC631 card at one of the ports labeled FIREWIRE on the
corresponding DF64 Digital Frame.
3) Attach the provided IEC compatible power cable to the IEC inlet.
Interface Pilot
1) Attach the RJ45 network cable connector to the port labeled LAN1.
2) Attach the TCC breakout cable to the DB62 connector on the TCC card lower
connector). This breaks out to 4-DB15 control lines.
3) Attach a 15 pin Dsub cable from control line #1 to the MC524 Monitor Interface.
4) Attach additional 15 pin Dsub cables from control lines 2, 3, and 4 to ML530 Mic-Line
Interfaces.
5) If more than 3 ML530s need to be connected, attach another TCC breakout cable to
the extension DB62 connector (upper) and connect DB15 cables the ML530 Mic-Line
Interfaces from control lines 5, 6, 7, and 8.
6) Attach a parallel port cable between the parallel ports on the Interface Pilot and the
MIDI interface.
Power On Sequence
1) The Studio Computer is powered on first when bringing up System 5.
2) Power on the Studio Hub, MIDI Express, TT007, Eucon Hub, and all converters.
3) Bring up the eMix software and power on the console, and the Interface Pilot and
Digital Pilot(s).
4) When the Digital Pilots indicate that their virtual mixers are loaded, the DF64 Digital
Frames can be powered on.
Power Down Sequence
Please use the following steps to power down the Studio Computer:
1) Shut down all applications. Press CTRL+ALT+* together to exit eMix.
2) From the Windows desktop, guide the mouse cursor into the lower left hand corner of
the monitor screen, the Start Bar will appear.
3) Left-click on the Start button on the lower left of the Start Bar. A menu will appear.
4) Left-click on the lowest item in the menu; Shut Down. A menu will appear.
5) Click on Shut Down. Click on OK.
6) Wait until you are presented with a screen that states, It is now safe to shut down the
computer.
7) Press the power button on the front of the Studio PC.