Installation manual
Euphonix CO-600 Change-Over System For New Core DF66 Redundancy
25
IP Conguration
Users may manually setup the IP address in the controller cards through the serial ports.
Use of Windows terminal or a similar interface is recommended.
NOTE: The IP address is already congured initially at the factory. Many users will
not need to execute this function.
Setup Serial Port 1.
For CM604, RS232 interface in CM606 is used. The serial port conguration is as
follows: 115200 baud rate, 8 bit data, none parity, 1 stop bit, No ow control.
For FC603, RS422 interface in FC605 is used. The serial port conguration is as
follows: 38400 baud rate, 8 bit data, none parity, 1 stop bit, No ow control.
Activate Serial Port
2.
For CM604, no action is needed.
For FC603, type “sq0” and press the RETURN or ENTER key.
Set IP Address
3.
Command for set Ethernet IP Address is “SE”.
Example: Entering the command, “SE 192.168.1.100 255.255.255.0 192.168.1.1”
will set the IP Address as “192.168.1.100”, the Mask as “255.255.255.0” and the
Gateway as “192.168.1.1.”
Provided below is a sample of the help screen and setting interface. Red italic characters
are user inputs. Points where the RETURN or ENTER key was pressed are not shown.
sq0NAKsq0Setting Quiet Mode to OFF
>H
Help Information:
Clear Fault (‘C’) Clears a logged fault on a card.
‘C [<card>]’
Display Status (‘D’) Displays a continually updating status screen.
‘D’
Flash Unit LED (‘F’) Flashes the Status LED on the front panel.
‘F’
Get Data (‘G’) Returns current value of a variable.
‘G <type> [data/options]’
Help (‘H’) Provides Help on a given command.
‘H [<command>]’
Reset (‘R’) Resets a card in the Frame.
‘R [<slot>]’
Set Data (‘S’) Sets a variable to a specic value.
‘S <type> [data/options]’
Self Test (‘T’) Preforms a specic self-test.