Installation manual
Euphonix CO-600 Change-Over System For New Core DF66 Redundancy
23
LED Indicators
LED indicators are provided to show relevant status information for the various
processes and faults in the CO-600 subsystems. Table 2 shows indicators and there
function on the various cards.
LED Card IndicatorsTable 2
LED Module (s) Color Behavior Description
OOS
CO601, CO602,
FC603, CM604,
FC605, CM606
blue
On continuously when permissible to ex-
tract card. Stays illuminated after insertion
until connection process completes.
Fault
CO601, CO602,
FC603, CM604
amber On continuously when fault detected
OK
CO601, CO602,
FC603, CM604
green
On continuously card is active, blinking
when card is not active.
Status FC603 green Period blink to indicate active
Fan CM605 green Fans OK
Temp CM605 green Temp OK
Power CM605 green Power OK
Power Good PS607 green Input voltage is within tolerance
Fault PS607 yellow / red Output inhibit/output voltage fault
A CO601 green MADI path A (primary)
B CO601 green MADI path B (backup)
MADI I/O A, B, C, D CO601 green MADI Signal Present
DSP A MADI A, B, C, D CO601 green MADI Signal Present
DSP B MADI A, B, C, D CO601 green MADI Signal Present
CO602 PinoutTable 3
CO602
COMBO D MADI I/O DSP A MADI DSP B MADI
A1 MOUT3 AOUT3 BOUT3
A2 MOUT2 AOUT2 BOUT2
A3 MOUT1 AOUT1 BOUT1
A4 MOUT0 AOUT0 BOUT0
A5 MIN3 AIN3 BIN3
A6 MIN2 AIN2 BIN2
A7 MIN1 AIN1 BIN1
A8 MIN0 AIN0 BIN0