Installation manual
Euphonix CO-600 Change-Over System For New Core DF66 Redundancy
22
Latency
The introduction of delay in the MADI signal path can have a detrimental effect on
the performance of the system. Latency has been kept to a minimum - less than 500
nanoseconds.
Hot Swap
All cards are capable of Hot-Swapping without interfering with the operation of the
other cards and components in the system.
Power
The power speciî‚¿cations for the PS-607 are listed below:
The PSUs is a universal AC Mains: AC: 100 to 240VAC, 50/60 Hz with PFC. 1.
Input Current: 2A max per input. 2.
Inrush current: 35 amps maximum3.
+5 VDC @ 25 amps, +3.3 VDC1 @ 30 amps, +12 VDC @ 1.5 amps, and -12 4.
VDC @ 0.5 amps.
Dual AC Inlets for Mains redundancy.
5.
Size: 3U cPCI 4 HP 200 watt PSUs. 6.
Current shared operation with automatic ability to operate on one PS-6077.