Installation manual

Euphonix CO-600 Change-Over System For New Core DF66 Redundancy
7
The CO-600 has two primary functions: 1) a MADI splitter that provides 2 MADI
outputs for each MADI input and 2) a MADI switchover that switches each MADI
output between Primary and Backup MADI sources. Figure 1 provides a conceptual
block diagram of signal ow and behavior. External MADI inputs are distributed to both
the Primary Core and the Secondary Core so that the sources are always available to both
cores. The MADI outputs from each core are connected to the CO-600 and available for
switchover during a technical fault. The unpowered state of the system is connectivity
to the Primary Core.
Signal Flow and BehaviorFigure 1
A conceptual block diagram of a single CO-600 is provided in Figure 2. Features
available include redundant PSU’s with dual IEC AC inlets, GPIO, Fan Tray, CMM,
Chassis Control module, Chassis control linking, environmental sensors, Ethernet, and
up to four Change-over cards.