SDS

文件名称
File Name
电池规格书
Battery Spec.
产品型号
Product model
18650(1INR19/66-4)
文件编号
Document No.
文件版本
Version
A2
日期
Date
2021-05-12
页码
Page
5/ 18
--- FUJI Confidential ---
4.3 标准充电 Standard charge
在环境温度为 25±2℃条件下, 0.2C 电流对电池充电,当电压到 4.2V 时,改为 4.2V 恒压充电,直到电流小于或等于
0.02C,停止充电,充电时间不大于 8h
Charge the battery at 0.2C to 4.2V at ambient temperature of 25±2, and then charge at constant voltage of 4.2V to
current less than or equal to 0.02C. Stop the charging. The charging time is not more than 8 hours.
4.4 标准放 Standard discharge
在环境温度为 25±2℃条件下,用 0.2C 放电到 2.8V
Discharge the battery at 0.2C to 2.8V at ambient temperature of 25±2℃.
5
、技术指标
Technical indicators
5.1、常规电性能 Conventional electrical properties
序号
No.
检验项目
Test item
检验方法
Test method
判定标准
Criteria
5.1.1 荷电保持能力及恢复
容量
Capacity retention
and recovered
capacity
电池 4.3 充电束后在环温度 25±2条件
下,将电池开路搁置 28d再以 0.2C 电流恒流放电至 2.8V
Charge the battery per section 4.3 and store the battery for
28 days at ambient temperature of 25 ±2. Discharge
the battery at constant current of 0.2 C to 2.8V.
85%×
Capacity 85% ×
Minimum Capacity.
5.1.2 存储性能
Storage
performance
4.3 40%45%
量,然 25±2湿 45%75%的环
12 4.3 充电后,在 25±2
0.2C 终止电压。充放电试验可以循
5
Before storage, charge the battery to 40% to 50% capacity
per section 4.3, After that, store the batteries at the
ambient temperature of 25±2 and relative humidity of
45% to 75% for 12 months and charge as per section 4.3,
and discharge at 0.2 C to the cut-off voltage. The charge
and discharge test may be cycled for 5 times.
75%×
Capacity 75% ×
Minimum Capacity.
5.1.3
循环寿命
Cycle life
在环境温度为 25±2℃条件下, 3A 充电,当电池端电压
达到 4.2V 时,改为压充,截电流 0.05C,总时间
不大于 8h搁置 0.5h然后以 3A 电流放电到终止电压,
电结束后,搁置 15min,再进行下一个充放电循环。
Charge the battery at 3A at ambient temperature of 25
±2 until voltage reaches 4.2V, and then charge at
constant current to current less than or equal to
0.05C.Total charging time should not be more than 8
hours. After that, store the battery for 0.5 hour and
discharge at 0.5C to the cut-off voltage. When the
discharge is finished, store the battery for 15 minutes
before proceeding to the next charge and discharge cycle.
500
持率在 80%以上。
Capacity retention
rate after 500 cycles
should be more than
80%