capacity higher than 75% of the initial capacity of
the battery.
电池以 0.2C 充饱,静置 10 分钟,然后以 0.2C 放空,
静置 10 分钟。重复以上充放电循环直至放电容量低于初
始容量的 75%。(请见附录电芯规格书)
9.3
Storage
Characteristic
荷电保持率
When the battery has completed standard
charged, it shall be disconnected and put aside for
28 Days at 25℃±3℃,Then measured the capacity
with 0.2 Cmin till FD Voltage.
将充满电后的电池在温度 25±3℃环境下存储 28 天,按
照标准的测试容量方法测试剩余容量。
Retention capacity >
85% Cmin
容量保持率> 85%
Cmin
9.4
Initial
Impedance
Using a AC 1KHZ meter whose precision must be
less than 0.5%, detect the resistance between the
battery’s positive and negative terminals. The
result value can not include any external
conductor’s resistance. The maximum and the
minimum need to be recorded.
使用 AC 1KHz 检测方法及准确度不低于 0.5 级的仪表,
测量电池接口处正负极之间的内阻值,若检测仪表在检测
过程中使用附加的电池固定夹具和引线,可以视情况减去
固定引线的电阻值,且记录最大与最小之差值。
The internal
resistance≤145mΩ
电池内阻值小于或等于
145mΩ。
9.5 ESD Test
Method: 5 times/pin , Frequency:1S/time
Non-operating:
Contact: ± 4KV ;Air: ± 8 KV
对电池组每个端子或者电路板的输出端子进行±4KV 接
触放电测试各 5 次和±8KV 空气放电测试各 5 次,每
两次放电测试时间间隔 1 分钟.
No explosion and no
fire. Its protection
function shall not
fail. if it is equipped
with protection
circuit.
电池组应不起火、不爆
炸,如有保护电路其保
护功能不应失效。
10. Reliability Test 可靠性测试
No. Item/项目 Test Method and Condition/测试方法和条件 Criteria/标准
10.1
Over-Voltage
Charge Test
过压充电测试
After standard charging, the battery is conducted
for 8 hours while the constant voltage is held at
4.6V/cell and standard charging current flows
through it.
将标准充电后的电芯,用恒定电压 4.6V/串和标准充电电
流给电池进行加压 8h.
No explosion, No fire
无爆炸、无起火
10.2
Short-circuit
Test
外部短路测试
Rest battery for 30min at 20 ± 5℃ after standard
charged. Connect between battery terminals with
copper lead (electric resistance: 80 mΩ±20mΩ)
and leave for 12hour.
将电池组充满电后,短路电池组的正负极端子,外部短路
总电阻为 80 mΩ±20mΩ。保持电池组短路 12h.
No explosion, No fire.
Max. Temp of
Battery surface
should not exceed
150℃。
无爆炸、无起火,电池