13. Technical Data: General
For further specifications see operating instruction enclosed to the product.
Parameters
Operation
with UL-class 2 power supply only
Electrical connection
Operating voltage U
B
DC 24 V ± 20%
Operating current, max. 100 mA
Communication interface
Type serial, RS 422A (4-wire)
Data format 8 data bits + 1 parity bit (even), 1 stop bit
Transfer speed
9 600 or 19 200 baud,
automatic detection
Transfer protocol Procedure 3964 R
Memory
Program memory (firmware) flash, 64 kbyte
Text data memory RAM, 32 kByte, volatile
2-stage enabling switches
Switching element 1 NO contact
Switching voltage, max. DC 30 V
Switching current, max. 0.1 A
Other components of the HBAS see EUCHNER catalog for handheld pendant stations
Accessories
Flange socket, 19-pin
Bracket
Active-X-Module
Demo and test software is available on the Internet at www.euchner.de