User Manual
EUCHNER Hand-Held Pendant Station
092491-07-01/09 Subject to technical modifications Page 28 / 34
Command
byte
Description Parameters
48H
Definition of an item
of text
Text number (31H...F9H),
Font size (50H or 51H),
Line (see table below),
Column (see table below),
Text: (21H...2C),(40H...43H), (80H...FFH)
49H
Output of a previously
defined item of text
Text number (31H...F9H)
Important!
The line and column information is dependent on the font size!
Font size Line Column
small
30H ... 37H 30H ... 3FH
large
30H ... 33H 30H ... 37H
Example:
Definition of text "Euchner" with small font in line 4 column 0 as text No. 5
The sequence for text and character sent must be observed
Control
system
STX 6CH 48H 35H 50H 34H 30H A5H D5H C3H C8H CEH C5H D2H ETX BCC
HBAS DLE DLE
Example:
Display of text No. 5
Control
system
STX 6CH 49H 35H ETX BCC
HBAS DLE DLE
Example:
Flashing display of text No. 5
Control
system
STX 6CH 42H 49H 35H 43H ETX BCC
HBAS DLE DLE
Example:
Definition of "Clear display" and text "EUCO" with small font, inverse display, at
the start of the display as text No. 6
Control
system
STX 6CH 48H 36H 50H 30H 30H 2BH 40H A5H B5H A3H AFH 41H ETX BCC
HBAS DLE
DLE