Electronic-Key-System Manual Electronic-Key Adapter with serial Interface Order No.
Manual EKS Electronic-Key Adapter serial Table of contents 1 General notes .............................................................................................................................................. 4 1.1 Use of the manual ................................................................................................................................. 4 1.2 CE conformity........................................................................................................................
Manual EKS Electronic-Key Adapter serial 7 Setup .......................................................................................................................................................... 14 8 Operating the Electronic-Key-System using the serial interface......................................................... 15 8.1 Special features of the serial interface ................................................................................................ 15 8.2 Communication .................
Manual EKS Electronic-Key Adapter serial 1 General notes 1.1 Use of the manual This manual describes the technical features and the function of the EKS Electronic-Key adapter EKS-A-ISX-G01-ST09/03 with serial interface (order no. 084 750). The complete evaluation and interface electronics are integrated in this unit. 1.
Manual EKS Electronic-Key Adapter serial 1.7 Explanation of symbols The following symbols are used in this manual to identify important instructions and useful information: Information! Important information is provided to the user here. Warning! Risk of damage to material or machine. Danger! Risk to life and limb. 1.
Manual EKS Electronic-Key Adapter serial 2 Safety precautions The Electronic-Key adapter must only be employed and used in accordance with this manual. The Electronic-Key adapter is typically operated as part of a higher-level overall system, e. g. a machine installation. When designing machines and using the Electronic-Key adapter, the national and international safety and accident prevention regulations specific to the application must be observed, e.g.: EN 60204, Safety of machinery.
Manual EKS Electronic-Key Adapter serial 3 Function 3.1 Functional description The EKS is used for access control and monitoring on control systems (PC/PLC) or parts of control systems for machine installations. Instead of passwords, coded Electronic-Keys are assigned. In this way unauthorized access to control and display systems is prevented to the greatest possible extent. The EKS uses a non-contact, inductive read/write identification system.
Manual EKS Electronic-Key Adapter serial 4 Technical data 4.1 Dimension drawing, Electronic-Key adapter/front panel cut-out 70,5 Front panel cut-out according to DIN 43700 40 60,7 LED max. 4mm 67 76 32 75 68 83 33 DIP switch M4 8 1,5 Rubber seal 8,5 32 51,5 4.2 Technical data, Electronic-Key adapter General parameters min.
Manual EKS Electronic-Key Adapter serial 4.3 Pin assignment 4.3.
Manual EKS Electronic-Key Adapter serial 4.4 DIP switch settings Using the DIP switches S1 to S8, various parameters can be set. Write protection can be enabled using DIP switch S1. In this way the writing of data to the Electronic-Key read/write is prevented. The settings are only applied when the power supply is switched on.
Manual EKS Electronic-Key Adapter serial 5 Mounting Mounting must be performed only by authorized personnel. To achieve the degree of protection IP 67, it is necessary to install the Electronic-Key adapter in a clean, flat metal plate at least 2 mm thick and to tighten the screws to a tightening torque of at least 0.25 Nm. The Electronic-Key adapter is intended for mounting in control panels with a cut-out measuring 33 mm x 68 mm according to DIN 43700 (see page 8 chapter 4.
Manual EKS Electronic-Key Adapter serial 6 Electrical connection Electrical connection may only be performed by authorized personnel trained in EMC and with the device and wiring isolated. For use and operation as per the be used. requirements, a power supply for use in class 2 circuits must The Electronic-Key adapter is only allowed to be connected if it is electrically isolated. Otherwise the Electronic-Key adapter may be damaged. If connected incorrectly, the Electronic-Key adapter may be damaged.
Manual EKS Electronic-Key Adapter serial 6.3 Serial interface connection 6.3.1 RS232 wiring diagram PC or PLC EKS TxD RxD GND OUT 9 - Pin 9 - Pin 2 3 4 5 6 7 8 2 3 4 5 6 7 8 25 - Pin Receive Data Transmit Data Data Term Ready Signal Ground Data Set Ready Request to Send Clear to Send 3 2 20 7 6 4 5 Shield 6.3.
Manual EKS Electronic-Key Adapter serial 7 Setup Setup is to be performed in the following sequence: 1. Set the DIP switches on the Electronic-Key adapter (see page 10 chapter 4.4). 2. Check mounting and electrical connection are correct (see page 11 chapter 5 Mounting and page 12 chapter 6 Electrical connection). 3. After the power supply is switched on, the LED on the front of the Electronic-Key adapter illuminates green. This indicates that the power supply is present. 4.
Manual EKS Electronic-Key Adapter serial 8 Operating the Electronic-Key-System using the serial interface 8.1 Special features of the serial interface If there is an Electronic-Key within the operating distance of the Electronic-Key adapter, the LED on the front changes from green to yellow. At the same time the OUT handshake signal (for use as CTS signal) changes from inactive (0) to active (1).
Manual EKS Electronic-Key Adapter serial 8.3.1 Special features of the 3964R data transfer protocol [1] The 3964R data transfer protocol is a comparatively reliable protocol for the electronic exchange of data between PC/control system and a peripheral connected, because the data transfer is performed using a standardized protocol. On control systems with an integrated 3964R driver (see e. g.
Manual EKS Electronic-Key Adapter serial The peripheral monitors the amount of time between the incoming characters. The gap between two characters must not be more than the character delay time (CDT, typically: 100 ms). All 10hex values contained in the message core must be sent twice so that the recipient recognizes that here information is being transferred and not the control character DLE (DLE duplication).
Manual EKS Electronic-Key Adapter serial 8.4 Commands for writing and reading an Electronic-Key read/write Write and read processes are always initiated by the PC/PLC (control system) using a "command message". The Electronic-Key-System then sends a reply message to the control system. PC/PLC (control system) Electronic-Key-System Command message −→ Reply message ← On Electronic-Keys read/write with 116 bytes, the memory is organized in 4-byte blocks.
Manual EKS Electronic-Key Adapter serial Byte no. Description 0 1 2 3 4 5 6 ASCII Number of message bytes Command identification R F Device address Padding data Status number Contents hexadecimal 07 52 46 01 00 00 * decimal 7 82 70 1 0 0 Figure 3: Reply message write Electronic-Key read/write - status (message core) * Status number 00hex: No error 02hex: Electronic-Key not in the operating distance (For further status numbers see chapter 8.7) 8.4.
Manual EKS Electronic-Key Adapter serial Byte no. Description 0 1 2 3 4 5 6 7 ... 122 Number of message bytes Contents hexadecimal decimal 08 ... 7B 8 ... 123 R 52 82 L 4C 76 01 1 00 0 00 ... 73 0 ... 115 01 ... 74 1 ... 116 ASCII or hexadecimal or BCD (code transparent) ASCII Command identification Device address Start address for the user data Number of bytes of user data User data Figure 5: Reply message read Electronic-Key read/write (message core) Byte no.
Manual EKS Electronic-Key Adapter serial 8.5 Command for resetting Using the command message TA the Electronic-Key adapter can be reset to its initial condition via the software. Command message (message core, PC/PLC → EKS, see Figure 7): TA (device addr.) (00hex, 00hex) (00hex) Reply message (message core, EKS → PC/PLC, see Figure 8): RF (device addr.) (00hex, 00hex) (00hex) The reply message RF with status number 00hex (see Figure 8) stands for correct processing of the cancel command. Byte no.
Manual EKS Electronic-Key Adapter serial 8.6 Command overview Description Program (write) Electronic-Key Read Electronic-Key (also read the serial number) Command message TP (see chapter 8.4.1) TL (see chapter 8.4.2 and 8.4.3) Reset device TA (see chapter 8.5) 8.7 Reply message RF (see chapter 8.4.1) RL (see chapter 8.4.2) or RF (see chapter 8.4.2) RF (see chapter 8.
Manual EKS Electronic-Key Adapter serial 9 Exclusion of liability Exclusion of liability under the following conditions: if the unit is not used for its intended purpose non-compliance with safety regulations if mounting and electrical connection are carried out by unauthorized personnel if modifications are made 10 Service and repair No servicing is required. Remove dirt from the Electronic-Key and the Electronic-Key adapter using a soft cloth and solvent-free, non-abrasive cleaning agents.
EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Telefon 0711 / 75 97 - 0 Telefax 0711 / 75 33 16 www.euchner.de . info@euchner.