Operating instructions Non-contact safety system CES-AZ-UBS-01B (Multicode) More than safety.
Operating Instructions Safety System CES-AZ-UBS-01B Contents Correct Use Possible combinations for CES components 3 4 Exclusion of Liability and Warranty 4 General Safety Instructions 5 Function Block diagram CES-AZ-UBS-01B 6 7 Installation 8 Electrical Connection Safety in case of faults Fusing of the power supply and the safety contacts 10 10 11 Connection examples CES-AZ-UBS-01B with read head CET CES-AZ-UBS-01B with standard read head 12 12 13 Commissioning LED indicators Functional Check
Operating Instructions Safety System CES-AZ-UBS-01B Correct Use The Coded Electronic Safety switches series CES are safety devices for monitoring movable safety guards. In combination with a separating safety guard and the machine control, this safety component prevents dangerous machine movements from occurring while the safety guard is open. A stop command is triggered if the safety guard is opened during the dangerous machine function.
Operating Instructions Safety System CES-AZ-UBS-01B Possible combinations for CES components 096327 CET-A-BWK-50X 095175 CEM-A-BH10 094805 CEM-A-BE05 098775 CES-A-BPA All items CES-A-NBA-... 098108 CES-A-BQA 077791 CES-A-BMB 084720 CES-A-BDA 088786 CES-A-BCA Read head 071840 Evaluation unit CES-A-BBA Actuator CES-A-LNA... All items CES-A-LNA-SC 077715 CES-A-LCA...
Operating Instructions Safety System CES-AZ-UBS-01B General Safety Instructions As the unique actuator codes are not evaluated, the CES-AZ-UBS-... version can only be used for applications in which a hazard cannot result from possible tampering with the system. Safety switches fulfill personal protection functions. Incorrect installation or tampering can lead to severe injuries to personnel. The number of teach-in and switching operations is saved in the internal memory in the evaluation unit.
Operating Instructions Safety System CES-AZ-UBS-01B Function The safety system CES-AZ-UBS... complies with the following safety requirements: Ì Category 3, PLe according to EN ISO 13849-1 Ì Proximity device with self-monitoring type PDF-M according to EN 60947-5-3. Ì Redundant design of the circuit in the evaluation unit with self-monitoring. As a result, the safety system is still effective even if a component fails.
Operating Instructions Safety System CES-AZ-UBS-01B Block diagram CES-AZ-UBS-01B Transponder Readhead 24 V, 0 V H11/H12 SH1 TST OUT ERR 13, 14 23, 24 Power supply Connection for read head 1 Shield for read head 1 Test input Semiconductor monitoring output Diagnostic output Relay contact A connection, safety relay enable Relay contact B connection, safety relay enable 24 V SH1 H11 H12 EUCHNER 13 23 14 24 + 24VDC CES-AZ-UBS-01B K1 100412 0V + K2 TST OUT ERR GND 7
Operating Instructions Safety System CES-AZ-UBS-01B Installation Caution! Safety switches must not be bypassed (bridging of contacts), turned away, removed or otherwise rendered ineffective. Ì On this topic pay attention in particular to the measures for reducing the possibility of bypassing according to EN 1088:1995.A2:2008, sec. 5.7. Ì The evaluation unit must be mounted in a control cabinet with a minimum degree of protection of IP 54.
Operating Instructions Safety System CES-AZ-UBS-01B Note the following points: Ì Actuator and read head must be easily accessible for inspection and replacement. Ì The switching operation must only be triggered by the specific actuator designated for this purpose. Ì Actuator and read head must be fitted so that Ì the front faces are at the minimum switch-on distance 0.8 x Sao or closer (see section Operating distances).
Operating Instructions Safety System CES-AZ-UBS-01B Electrical Connection Warning! In case of an error, loss of the safety function through incorrect connection. Ì The monitoring output OUT must not be used as a safety output. Ì Lay the connection cables with protection to prevent the risk of short circuits. Caution! Risk of damage to equipment or malfunctions as a result of incorrect connection.
Operating Instructions Safety System CES-AZ-UBS-01B Fusing of the power supply and the safety contacts Ì Provide external contact fuses (6 A gG fuse or 6 A circuit breaker, characteristic B or C) for relay outputs. Ì The power supply must be protected with a max. 8 A fuse before terminal UB.
Operating Instructions Safety System CES-AZ-UBS-01B Connection examples CES-AZ-UBS-01B with read head CET 24VDC 6 -S1 4 24V CET1-AX-LRA-00-50X-SA head Read- Actuator 095735 -F2 -F1 LED1 EUCHNER LED2 SH1 H11 H12 8 3 2 1 7 5 PLC -A1 24V CES-AZ-UBS-01B SH1 H11 H12 100412 24VDC 23 L1 L2 L3 + K2 EUCHNER 0V 13 + K1 TST OUT ERR GND 14 24 11 -V1 -K3 12 21 -V2 -K4 22 feedback loop -M1 M 3~ GND Important! To achieve category 3 according to EN ISO 13849-1, it is necessa
Operating Instructions Safety System CES-AZ-UBS-01B CES-AZ-UBS-01B with standard read head 24VDC 24V -F1 -F2 Transponder Readhead PLC -A1 24V CES-AZ-UBS-01B SH1 H11 H12 100412 L2 L3 + K2 EUCHNER 0V L1 + K1 24VDC 23 13 TST OUT ERR GND 14 24 11 -V1 -K3 12 21 -V2 -K4 22 feedback loop -M1 M 3~ GND Important! To achieve category 3 according to EN ISO 13849-1, it is necessary to monitor the downstream contactors (here contacts of -K3 and -K4 in the feedback loop).
Operating Instructions Safety System CES-AZ-UBS-01B Commissioning LED indicators STATE LED green Normal operation Flashing Teach-in operation (for further signal function see status table) OUT LED yellow Valid actuator detected ERROR LED red - Test input activated - Internal electronics fault (see status table on Page 17) In case of an operating fault, the evaluation unit can be reset to the operating state by interrupting the power supply for approx. 10 seconds.
Operating Instructions Safety System CES-AZ-UBS-01B Self-test with test input TST On electromechanical safety switches or magnetic switches, the function test can be performed by cyclically opening the safety guard. From category 2 according to EN ISO 13849-1 and in accordance with EN 60204-1 : 1997 (sec. 9.4.2.4), a function test must be performed on the entire safety system on start-up or after defined intervals.
Operating Instructions Safety System CES-AZ-UBS-01B System Status Table PLC LED display Output Safety outputs 13/14 and 23/24 TST OUT (status signal) ERR Output Actuator/ Guard position In- closed on N 1 0 Normal operation, door closed. open off N 0 0 Normal operation, door open.
Operating Instructions Safety System CES-AZ-UBS-01B Technical Data Evaluation unit CES-AZ-UBS-01B Ì Housing for DIN rail mounting, IP 20 Ì 2 safety contacts (relay contacts) Ì 2 internal NO contacts per safety contact Ì 1 read head can be connected Dimension drawing 114 22,5 H11 H12 SH1 24V 0V CES STATE 99 Approvals OUT ERROR TST OUT ERR GND 13 14 23 24 Suitable for standard 35 mm DIN rail Switching characteristics Ì 2 safety contacts (relay contacts) Ì 1 door monitoring contact Safety guard
Operating Instructions Safety System CES-AZ-UBS-01B Technical Data Value Parameter min. typ. Housing material max. Unit Plastic PA6.6 Dimensions 114 x 99 x 22.5 Weight mm 0.
Operating Instructions Safety System CES-AZ-UBS-01B Ordering table Series Category according to EN ISO 13849-1 Typ. switch-on distance [mm] Number of read heads Order no. / item CES-AZ-UBS...
Operating Instructions Safety System CES-AZ-UBS-01B Read head CES-A-LNA-... Ì Cube-shaped design 42 x 25 mm Ì Hard-wired cable Approvals Dimension drawing "l" 42 2 safety screws M4 x 14 included 25 CES-A-L XXXXXX 8 4,5 12 32 ±0,1 Active face 4,6 Active face Typical operating distance With evaluation unit CES-AZ-UBS-...
Operating Instructions Safety System CES-AZ-UBS-01B Technical Data Parameter Value min. Housing material typ. Unit max. Fortron, reinforced thermoplastic, fully encapsulated Dimensions 42 x 25 x 12 Weight (incl. 10 m cable) mm 0.
Operating Instructions Safety System CES-AZ-UBS-01B Read head CES-A-LNA-SC Ì Cube-shaped design 42 x 25 mm Ì M8 plug connector (snap-action and screw terminals) Approvals Dimension drawing 32,6 42 12 32 ±0,1 8 4,6 10 4,5 6,8 25 CES-A-L 077715 3 A0 Active face 1 min.38 Active face 4 5,5 2 safety screws M4 x 14 included Cable outlet with angled connector 26,5 CES-A-L 077715 A0 20,1 Typical operating distance With evaluation unit CES-AZ-UBS-...
Operating Instructions Safety System CES-AZ-UBS-01B Pin assignment Read head with plug connector WH Screen BN H11 H12 SH1 4 3 1 View on plug connector of the read head Evaluation unit CES-AZ-UBS-... Technical Data Parameter Value min. Housing material Unit typ. max. Fortron, reinforced thermoplastic, fully encapsulated Dimensions 42 x 25 x 12 Weight (incl. 10 m cable) mm 0.
Operating Instructions Safety System CES-AZ-UBS-01B Read head CES-A-LCA-... Ì Cube-shaped design 42 x 25 mm Ì Plastic PE-HD housing material, suitable for use in aggressive media (e.g. ac- Approvals ids, alkalis) Dimension drawing 48 14 42 12 ± 0,1 4,6 31 25 8 4,5 32 Active face Flat seal Active face l 2 safety screws M4 x 14 included Note The flat seal provided must be used during assembly. Typical operating distance With evaluation unit CES-AZ-UBS-...
Operating Instructions Safety System CES-AZ-UBS-01B Pin assignment Read head with connection cable Screen BN WH Read head View on plug connector of the read head H11 H12 SH1 Evaluation unit CES-AZ-UBS-... Technical Data Parameter Value min. typ. Unit max. Housing material Plastic PE-HD without reinforcement, fully encapsulated Flat seal material Fluororubber 75 FPM 4100 Dimensions 42 x 25 x 12 Weight (incl. 10 m cable) mm 0.
Operating Instructions Safety System CES-AZ-UBS-01B Read head CES-A-LQA-SC Ì Cube-shaped design 50 x 50 mm Ì M8 plug connector (snap-action and screw terminals) Dimension drawing 0 Ø 4,5 0 50 - 0,25 M 8x1 7 40 ±0,15 6 Active face Typical operating distance Y 30 20 -30 10 10 10 20 20 30 30 Z X -30 With actuator CES-A-BBA or CES-A-BCA Y 30 20 10 10 10 20 20 30 X 30 Z with actuator CES-A-BQA on evaluation unit CES-A-UBS-01B 26 40 ±0,15 50 - 0,25 20,2 20 Approvals
Operating Instructions Safety System CES-AZ-UBS-01B Pin assignment Read head with connection cable Screen BN WH H11 H12 4 1 3 Read head SH1 Evaluation unit CES-A-UBS-01B Technical Data Parameter Value min. Housing material typ. Unit max. Fortron, reinforced thermoplastic, fully encapsulated Dimensions 50 x 50 x 20.2 Weight mm 0.
Operating Instructions Safety System CES-AZ-UBS-01B Read head CES-A-LMN-SC Ì Cylindrical design M12 Ì M8 plug connector (snap-action and screw terminals) Approvals Dimension drawing Reading distance s 17 4 35 m Centre offset Active face M 8x1 19,7 M 12x1 32 1) connected 5 1) 8 30 37 1) Clear zone (area of the active face without metal housing) Note The read head is allowed to be installed as a maximum up to the clear zone (area of the active face without metal housing).
Operating Instructions Safety System CES-AZ-UBS-01B Pin assignment Read head with plug connector WH Screen BN H11 H12 SH1 4 3 1 View on plug connector of the read head Evaluation unit CES-AZ-UBS-... Technical Data Parameter Value min. Unit typ. Housing material max. Nickel-plated CuZn housing sleeve Plastic PBT GF20 cap Dimensions M12 x 1, length 38 Weight (incl. 10 m cable) mm 0.
Operating Instructions Safety System CES-AZ-UBS-01B Actuator CES-A-BBA/CES-A-BCA Ì Cube-shaped design 42 x 25 mm Ì CES-A-BCA suitable for use in aggressive media (e.g. acids, alkalis) Ì In combination with read head CES-A-LNA.../CES-A-LCA...
Operating Instructions Safety System CES-AZ-UBS-01B Actuator CES-A-BQA Ì Cube-shaped design 50 x 50 mm Dimension drawing CES-A-BQA 0 50 - 0,25 Ø 4,5 0 50 - 0,25 40 ±0,15 20,2 40 ±0,15 6 Active face Technical Data Value Parameter min. Housing material typ. Unit max. Fortron, reinforced thermoplastic, fully encapsulated Dimensions 50 x 50 x 20.2 Weight mm 0.
Operating Instructions Safety System CES-AZ-UBS-01B Actuator CES-A-BDA Ì Round design ∅ 20 mm Ì In combination with read head CES-A-LNA.../CES-A-LCA... Dimension drawing ∅ 20 Active face Active face 2,2 Technical data Value Parameter min. typ. Housing material Plastic PC Dimensions ∅ 20 x 2.2 Weight max. mm 0.
Operating Instructions Safety System CES-AZ-UBS-01B Actuator CES-A-BMB Ì Cylindrical design M12 x 75 Ì In combination with read head CES-A-LMN-SC (with read head CES-A-LNA.../LCA... operating distance on request) Dimension drawing 6 11 M12x0,75 0,80 Active face Notes Ì The actuator can be screwed into the M12 x 0.75 thread provided with the aid of an insertion tool (Order No. 037 662). Ì Flush installation of the actuator in steel is allowed. Technical Data Value Parameter min. typ.
Operating Instructions Safety System CES-AZ-UBS-01B Inspection and Service Warning! Loss of the safety function because of damage to the device. In case of damage, the related safety component must be replaced. The replacement of individual parts in a safety component is not permitted.
Operating Instructions Safety System CES-AZ-UBS-01B Declaration of Conformity 35
Operating Instructions Safety System CES-AZ-UBS-01B 36
Operating Instructions Safety System CES-AZ-UBS-01B 37
Euchner GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen info@euchner.de www.euchner.de Issue: 100414-11-10/13 Title: Operating Instructions Safety System CES-AZ-UBS-01B (translation of the original operating instructions) Copyright: © EUCHNER GmbH + Co. KG, 10/2013 Subject to technical modifications, all data supplied without liability. More than safety.