User Manual

Operating Instructions Safety Switches CES-AR-C.2-AH
22
Teach-in function for series connection
It is recommended not to teach in the actuators in the series connection but to 
teach them in one by one instead. Teach-in in a series connection works analo-
gously to individual operation in principle. All switches in the chain can be taught 
in at the same time. The prerequisite is that the switch chain functions without 
errors and the following
steps are complied with. Further steps might have  to observed for mixed switch 
chains (e.g. for chains with CES and safety switches with guard locking). Observe 
the operating instructions for the other devices in the chain for this purpose.
Proceed as follows:
1.  Mount the switches and actuators and fully connect them (see e. g. Figure 5 
or Figure 6)
2.  Close all safety doors in the chain.
3.  Switch on the power supply.
¨ The green LED STATE flashes at approx. 1 Hz on the safety switches and the 
associated actuators are taught in. This happens for approx. 1 minute. Do not 
switch off during this time and do not actuate reset! The teach-in operation has 
ended when all LEDs on the safety switches are off.
4.  Actuate the reset for at least 3 s (24 V on RST)
¨ The system restarts and then functions in normal operation.
Replacing and teaching-in device
Work on the wiring (e.g. during device replacement) generally should be performed 
in a de-energized state. On certain systems, it is nevertheless necessaryto perform 
this work and subsequent teach-in during ongoing operation.
Input RST must be connected as shown in Figure 5 to permit this.
Proceed as follows:
1.  Open the safety door on which the switch or actuator is to be replaced.
2.  Mount the new switch or actuator and fully connect them.
3.  Close all safety doors in the chain.
4.  Actuate the reset for at least 3 s (24 V on RST).
¨ On the safety switch that is positioned at a new actuator, the green LED flashes 
at approx. 1 Hz and the actuator is taught-in. This happens for approx. 1 min-
ute - do not switch off during this time and do not  actuate reset! The teach-in 
operation has ended when all LEDs on the device are off.
5.  Actuate the reset for at least 3 s (24 V on RST).
¨ The system restarts and then continues to function in normal operation.