Manual

Operating Instructions AR Evaluation Unit CES-AR-AES-12
3
Correct use
The AR evaluation unit is used for the central evaluation of safety-related signals 
in AR switch chains.
In combination with a separating safety guard and the machine control, this safety 
component  prevents dangerous  machine  movements  from  occurring  while  the 
safety guard is open. A  stop command is triggered if the safety guard is opened 
during the dangerous machine function or if guard locking is deactivated. 
Before safety switches are used, a risk assessment must be performed on the 
machine in accordance with:
Ì EN ISO 13849-1, Safety of machinery. Safety related parts of control systems. 
General principles for design
Ì EN ISO 12100, Safety of machinery – General principles for design – Risk as-
sessment and risk reduction.
Ì IEC 62061, Safety of machinery. Functional safety of safety-related electrical, 
electronic and programmable electronic control systems.
Correct use includes compliance  with the relevant requirements  for installation 
and operation, in particular
Ì EN ISO 13849-1, Safety of machinery. Safety related parts of control systems. 
General principles for design
Ì EN 1088, Safety of machinery. Interlocking devices associated with guards. 
Principles for design and selection
Ì EN 60204-1, Safety of machinery. Electrical equipment of machines. General 
requirements
Ì EN 60947-5-3 Specification for low-voltage switchgear and controlgear. Con-
trol circuit devices and switching elements. Requirements for proximity devices 
with defined behavior under fault conditions
Only safety switches that are suitable for operation in an AR switch chain can be 
evaluated. Check the operating instructions for the related safety switch. Combina-
tion with devices that are not suitable for use in an AR switch chain or with devices 
from other manufacturers is not permitted. A maximum of 12 safety switches in 
an AR switch chain can be connected to the AR evaluation unit CES-AR-AES-12.
Unicodeand Multicodeversion switches can be connected. Unicodeand Multicode
versions can be combined in an AR switch chain.
Important!
Ì The user is responsible for the integration of the device into a safe overall 
system. For this purpose, the overall system must be validated, e.g. in ac-
cordance with EN ISO 13849-2.
Ì Correct use requires observing the permissible operating parameters (see 
Technical data).
Ì If a product data sheet is included with the product, the information on the 
data sheet applies in case of discrepancies with the operating instructions.
Ì In the estimation of the PL for the overall system, a maximum value of 
100 years can be assumed for the MTTF
d
 according to the limit value in 
EN ISO 13849-1:2008, section 4.5.2. This corresponds to a minimum value 
for the PFH
d
 of 2.47x10
-8
/h. 
Ì When up to 11 devices are connected in series, these limit values can be 
assumed for the entire switch chain as a subsystem. As a subsystem, this 
switch chain achieves PL e.