Operating instructions Non-contact safety system CES-A-UEA-02B/CES-A-UEA-04B (Multicode) More than safety.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Contents Correct Use Possible combinations for CES components 3 4 Exclusion of Liability and Warranty 4 General Safety Instructions 5 Function Block diagram CES-A-UEA-02B Block diagram CES-A-UEA-04B 6 7 8 Installation 9 Electrical Connection Safety in case of faults Fusing of the power supply and the safety contacts Connection example CES-A-UEA-02B Connection example CES-A-UEA-04B 11 12 12 13 14 Setup LED indicators Parameter sett
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Correct Use The Coded Electronic Safety switches series CES are safety devices for monitoring movable safety guards. In combination with a separating safety guard and the machine control, this safety component prevents dangerous machine movements from occurring while the safety guard is open. A stop command is triggered if the safety guard is opened during the dangerous machine function.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Possible combinations for CES components 096327 CET-A-BWK-50X 095175 CEM-A-BH10 094805 CEM-A-BE05 098775 CES-A-BPA All items CES-A-NBA-... 098108 CES-A-BQA 077791 CES-A-BMB 084720 CES-A-BDA 088786 CES-A-BCA Read head/safety switch 071840 Evaluation unit CES-A-BBA Actuator CES-A-LNA... All items CES-A-LNA-SC 077715 CES-A-LCA...
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B General Safety Instructions As the unique actuator codes are not evaluated, the CES-A-UEA... version can only be used for applications in which a hazard cannot result from possible tampering with the system. Safety switches fulfill personal protection functions. Incorrect installation or tampering can lead to severe injuries to personnel. The number of teach-in and switching operations is saved in the internal memory in the evaluation unit.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Function The safety system CES-A-UEA... complies with the following safety requirements: Ì Category 4, PLe according to EN ISO 13849-1 Ì Proximity device with self-monitoring type PDF-M according to EN 60947-5-3. Ì Redundant design of the circuit in the evaluation unit with self-monitoring. As a result, the safety system is still effective even if a component fails.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Operating voltage 0V DC + 24 V UB Transponder A Kopf Head11 J1 0V J2 H11 H12 Transponder B Read heads Activation of the teach-in operation with jumper on J1, J2 Coded actuators Block diagram CES-A-UEA-02B SH1 Kopf Head 2 2 H21 H22 SH2 Head -- HF RF -- Multiplexer multiplexer Kopf 2) 4 ) ((11of aus Head selection LED Demodulator Filter Verstärker Amplifier Komparator Comparator STAT E OUT STAT E O U T DIA DIA ON 1 2
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Block diagram CES-A-UEA-04B Activation of the teach-in operation with jumper on J1, J2 Operating voltage DC 0 V + 24 V UB J2 J1 0V TransTransponder ponder TransTransponder ponder TransTransponder ponder Transponder ponder A B C D Kopf Head 11 Kopf Head 2 Kopf Head 3 opf 44 Head H11 H12 SH1 H21 H22 SH2 H31 H32 SH3 H41 H42 Coded actuators Read heads SH4 Head -RF - mulitplexer K 4) 4 ((11of aus Head selection LED
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Installation Caution! Safety switches must not be bypassed (bridging of contacts), turned away, removed or otherwise rendered ineffective. Ì On this topic pay attention in particular to the measures for reducing the possibility of bypassing according to EN 1088:1995.A2:2008, sec. 5.7. Ì The evaluation unit must be mounted in a control cabinet with a minimum degree of protection of IP 54.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Note the following points: Ì Actuator and read head must be easily accessible for inspection and replacement. Ì The switching operation must only be triggered by the specific actuator designated for this purpose. Ì Actuator and read head must be fitted so that Ì the front faces are at the minimum switch-on distance 0.8 x Sao or closer (see section Operating distances).
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Electrical Connection Warning! In case of an error, loss of the safety function through incorrect connection. Ì To ensure safety, both safety outputs (13/14 and 23/24) must always be evaluated. Ì The monitoring output OUT must not be used as a safety output. Ì Lay the connection cables with protection to prevent the risk of short circuits. Caution! Risk of damage to equipment or malfunctions as a result of incorrect connection.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Safety in case of faults Ì The operating voltage UB is reverse polarity protected. Ì The connections for the read heads are not short circuit-proof. Ì A short circuit between 13/14 and 23/24 can be detected only by means of external pulsing. Ì A short circuit in the cable can be excluded by laying the cable with protection.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Connection example CES-A-UEA-02B 24 VDC -F1 Transponder Transponder Readhead 1 Readhead 2 -F2 L1 -K1 EUCHNER 0V UB J1 J2 SH1 H11H12 SH2 H21H22 L2 L3 13 23 33 14 24 34 CES-A-UEA-02B TST 097077 O1 O2 O3 O4 DIA 23 24 13 14 Y1 Y2 S Start -K2 13 23 14 21 -K2 22 21 A1 -V1 -K1 A2 A1 -V2 -K2 -M1 24 33 34 M 3~ -K1 22 A2 feedback loop GND Important! To achieve category 4 according to EN ISO 13849-1, it is
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Connection example CES-A-UEA-04B 24 VDC -F1 Transponder Transponder Transponder Transponder Readhead 1 Readhead 2 Readhead 3 Readhead 4 -F2 L1 0V UB J1 J2 SH1 H11 H12 SH2 H21H22 SH3 H31H32 SH4 H41H42 CES-A-UEA-04B TST 097075 O1 -K1 EUCHNER O2 O3 O4 DIA 23 24 13 14 Y1 Y2 S L2 L3 13 23 33 14 24 34 Start 13 -K2 23 14 24 33 34 21 -K2 22 21 A1 -V1 -K1 A2 A1 -V2 -K2 -K1 -M1 M 3~ 22 A2 feedback loop GN
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Setup LED indicators STATE LED green State display (multifunction display using flashing modes) OUT LED yellow Safety circuit closed DIA LED red - Operating error or - External fault (fault in the feedback loop) or - Teach-in process not valid or - Internal device fault or - TST input activated (function test active) Parameter setting Before the system forms a function unit, the parameters are set in the evaluation unit by the user (n
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B 2.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Functional check After installation and any fault, the safety function must be fully checked. Proceed as follows: Warning! Danger of fatal injury as a result of faults in installation and functional check. Ì Before carrying out the functional check, make sure that there are no persons in the danger area. Ì Observe the valid accident prevention regulations. 1. Switch on operating voltage. Ì The safety switch carries out a self-test.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B System Status Table Setup State DIA (red) OUT (yellow) Operating mode STATE (green) LED 4 Hz Initial setup after delivery without jumper connected to J1, J2. 1 Hz parameter setting operation Acknowledgement of completion of parameter setting operation. 15 Hz (10 s) Self-test, duration approx. 10 seconds, is performed after the application of the operating voltage UB Normal operation, not all monitored doors are closed.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Technical Data Note! If a product data sheet is included with the product, the information on the data sheet applies in case of discrepancies with the operating instructions.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Technical Data Value Parameter min.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Ordering table Series Category according to EN ISO 13849-1 Number of read heads Order no. / item CES-A-UEA...
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Evaluation unit CES-A-UEA-04B Ì Housing for DIN rail mounting, IP 20 Ì Relay output Ì 4 read heads can be connected Dimension drawing 45 114 99 Approvals Suitable for 35-mm DIN rail according to EN 60715 Switching characteristics Ì 2 safety outputs (relay outputs) Ì 4 door monitoring outputs Safety guard closed (all actuators detected) Read head 1 Actuator 1 Open (e.g.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Technical Data Value Parameter min.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Ordering table Series Category according to EN ISO 13849-1 Number of read heads Order no. / item CES-A-UEA...
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Read head CES-A-LNA... Ì Cube-shaped design 42 x 25 mm Ì Hard-wired cable Approvals Dimension drawing "l" 42 2 safety screws M4 x 14 are supplied 32 ±0,1 25 CES-A-L XXXXXX 8 4,5 12 Active face 4,6 Active face Typical operating distance With evaluation unit CES-A-UEA...
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Technical Data Parameter Value min. Housing material typ. Unit max. Fortron, reinforced thermoplastic, fully encapsulated Dimensions 42 x 25 x 12 Weight (incl. 10 m cable) mm 0.3 Ambient temperature -25 - Degree of protection kg +70 °C IP67/IP69K Installation position Any Method of operation Inductive Power supply Via evaluation unit In combination with actuator CES-A-BBA on evaluation unit CES-A-UEA...
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Read head CES-A-LNA-SC Ì Cube-shaped design 42 x 25 mm Ì M8 plug connector (snap-action and screw terminals) Approvals Dimension drawing 32,6 42 12 32 ±0,1 8 4,6 10 4,5 6,8 25 CES-A-L 077715 3 A0 Active face 1 min.38 4 5,5 Active face 2 safety screws M4 x 14 are supplied Cable outlet with angled connector 26,5 CES-A-L 077715 A0 20,1 Typical operating distance With evaluation unit CES-A-UEA...
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Pin assignment Read head with plug connector WH Screen BN H11 H12 SH1 4 3 1 View on the plug connector of the read head Evaluation unit CES-A-UEA... Technical Data Parameter Value min. Housing material Unit typ. max. Fortron, reinforced thermoplastic, fully encapsulated Dimensions 42 x 25 x 12 Weight (incl. 10 m cable) mm 0.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Read head CES-A-LCA... Ì Cube-shaped design 42 x 25 mm Ì Plastic PE-HD housing material, suitable for use in aggressive media (e.g. ac- Approval ids, alkalis) Dimension drawing 48 14 42 12 ± 0,1 4,6 31 25 8 4,5 32 Active face Flat seal Active face l 2 safety screws M4 x 14 are supplied Note The flat seal provided must be used during assembly.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Pin assignment Read head with connection cable Screen BN WH Read head View on the plug connector of the read head H11 H12 SH1 Evaluation unit CES-A-UEA... Technical Data Parameter Value min. typ. Unit max. Housing material Plastic PE-HD without reinforcement, fully encapsulated Flat seal material Fluororubber 75 FPM 4100 Dimensions 42 x 25 x 12 Weight (incl. 10 m cable) mm 0.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Read head CES-A-LQA-SC Ì Cube-shaped design 50 x 50 mm Ì M8 plug connector (snap-action and screw terminals) Dimension drawing 0 Ø 4,5 0 50 - 0,25 M 8x1 7 40 ±0,15 6 Active face Typical operating distance Y 30 20 -30 10 10 10 20 20 30 30 Z X -30 With actuator CES-A-BBA or CES-A-BCA Y 30 20 10 10 10 20 20 30 X 30 Z with actuator CES-A-BQA on evaluation unit CES-A-UEA-...
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Pin assignment Read head with connection cable Screen BN WH H11 H12 4 1 3 Read head SH1 Evaluation unit CES-A-UEA-... Technical Data Parameter Value min. Housing material typ. Unit max. Fortron, reinforced thermoplastic, fully encapsulated Dimensions 50 x 50 x 20.2 Weight mm 0.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Read head CES-A-LMN-SC Ì Cylindrical design M12 Ì M8 plug connector (snap-action and screw terminals) Approvals Dimension drawing Reading distance s 17 4 35 m Centre offset Active face M 8x1 19,7 M 12x1 32 1) connected 5 1) 8 30 37 1) Clear zone (area of the active face without metal housing) Note The read head is allowed to be installed as a maximum up to the clear zone (area of the active face without metal housing).
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Pin assignment Read head with plug connector WH Screen 4 BN H11 H12 SH1 3 1 View on the plug connector of the read head Evaluation unit CES-A-UEA... Technical Data Parameter Value min. Unit typ. Housing material max. Nickel-plated CuZn housing sleeve Plastic PBT GF20 cap Dimensions M12 x 1, length 38 Weight (incl. 10 m cable) mm 0.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Actuator CES-A-BBA/CES-A-BCA Ì Cube-shaped design 42 x 0.98 in Ì CES-A-BCA suitable for use in aggressive media (e.g. acids, alkalis) Ì In combination with read head CES-A-LNA.../CES-A-LCA...
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Actuator CES-A-BQA Ì Cube-shaped design 50 x 50 mm Dimension drawing CES-A-BQA 0 50 - 0,25 Ø 4,5 0 50 - 0,25 40 ±0,15 20,2 40 ±0,15 6 Active face Technical Data Value Parameter min. Housing material typ. Unit max. Fortron, reinforced thermoplastic, fully encapsulated Dimensions 50 x 50 x 20.2 Weight mm 0.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Actuator CES-A-BDA Ì Round design ∅ 20 mm Ì In combination with read head CES-A-LNA.../CES-A-LCA... Dimension drawing Active face Active face 20 2,2 Technical data Value Parameter min. typ. Housing material Plastic PC Dimensions ∅ 20 x 2.2 Weight max. mm 0.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Actuator CES-A-BMB Ì Cylindrical design M12 x 75 Ì In combination with evaluation units CES-A-UEA..., read head CES-A-LMN-SC (operating distance on request for read head CES-A-LNA.../LCA...) Dimension drawing 6 11 M12x0,75 0,80 Active face Notes Ì The actuator can be screwed into the M12 x 0.75 thread provided with the aid of an insertion tool (Order No. 037 662). Ì Flush installation of the actuator in steel is allowed.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Inspection and service Warning! Loss of the safety function because of damage to the device. In case of damage, the related safety component must be replaced. The replacement of individual parts in a safety component is not permitted.
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B Declaration of Conformity 40
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B 41
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B 42
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B 43
Euchner GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen info@euchner.de www.euchner.de Issue: 097098-14-10/13 Title: Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B (translation of the original operating instructions) Copyright: © EUCHNER GmbH + Co. KG, 10/2013 Subject to technical modifications, all data supplied without liability. More than safety.