Instruction Manual
System Manual Safety System CES-A-S5H01
21
Technical Data
Note
If a product data sheet is included with the product, the information on the data
sheet applies in case of discrepancies with the operating instructions.
Safety switch CES-A-S5H-01
Read head and evaluation unit integrated in the standard housing
Semiconductor output
M12 plug connector
Dimension drawing
Switching characteristics
2 safety outputs
(semiconductor outputs)
4 data outputs for actuator
number (semiconductor
outputs, not safety output)
Note
The data outputs D0, D1, D2, D3 have no safety function.
The safety outputs LA and LB as well as the data outputs D0, D1, D2, D3 are
short circuit-proof.
Typical operating distance
See page 24 and page 27
ApprovalsApprovals
±0,1
Ø
60
M x1
7,3
30
5,3
±0,1
7,3
23
23
46,5
119
D3 D2 D1 D0
16,5
12,5
40
40,5
LED
State
indica-
tion
LED indicator:
dog number
Active face
Safety guard
closed
(actuator detected)
open
(actuator not in the operating
distance)
Read head
Safety
actuator
Read head
+LA
LA
+LB
LB
24 V D0
+LA
LA
+LB
LB
24 V
D0
24 V
D1
24 V
D2
24 V
D3
24 V
D1
24 V
D2
24 V
D3