Instruction Manual
System Manual Safety System CES-A-S5H01
16
Pin assignment safety switch CES-A-S5...
LED indicators
STATE LED green Normal operation
Flashing Teach-in operation (for further signal function
see status table)
OUT/ERROR LED yellow Valid actuator detected
LED red - Internal electronics fault
- Invalid teach-in operation
(see status table)
D0, D1, D2, D3 LED yellow Indication of the actuator number in binary
code
Reset
In case of an operating fault, the evaluation unit can be reset to the operating state
by interrupting the power supply for approx. 10 seconds.
1
2
3
4
5
6
7
8
9
10
11
12
1 LA 7 NC
2 + LA 8 D0
3
+ UB 9 D1
4
+ LB 10D2
5
LB 11 D3
6 0 V 12 NC
View of connection side of the device
The screen on the connection cable is con-
nected internally to the device screen bond-
ing clamp via the knurled nut on the M12
plug connector.