Owner's manual
Operating Instructions Read Head CEM-A-LE05H-S2
EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49/711/75 97-0 Fax +49/711/75 33 16 www.euchner.de info@euchner.de
Terminal assignment
2
1
4
3
X1 X3
1
4
3
X1/M8 male socket X3/M8 male socket
CM
X1.4
X1.2
X1.1
X1.3
A free-wheeling diode is already integrated
into each CEM.
Solenoid
Solenoid
Pin Description
X1.1 U
CM
DC 24 V
X1.2 U
B
DC 24 V
X1.3 0 V GND
X1.4
Evaluation unit cable
Pin Description
X3.1 Data wire
X3.3 Data wire
X3.4 SH1 (screen)
Figure 4: Terminal assignment
Article Description Order no.
CEM-A-LE05H-S2-104606
Read head CEM with 500 N locking force and adjustable adhesive force
(30 N, 50 N, 80 N), factory setting 50 N
104 606
CEM-A-BE05
Actuator CEM for read heads with locking force of 500 N
094 805
CEM-A-ZPS-110013
Programming adapter for setting the adhesive force
110 013
Table 1: Ordering table
Ordering table
50
40
±0,10
5,4
80
65
Ø48
49,5
7
14,5
4°
4°
8
24,5
X
Active
face
Solenoid
16
∅ 50
40
±0,10
5,4
49,5
7
14,5
80
65
50
8
8
28
X3: Connection
read head
Active
face
X1: Connection
operating voltage
Solenoid
LED
Figure 3: Dimension drawing
Dimension drawing
48,5
8,3
M8x1
96,4
3 4
21
1
2
4 3