AS-i Safety Monitor for 2 AS-i circuits
Diagnostics for AS-i Monitor and networking using AS-i Master
11.4.3.1 Vendor Specific Object 2 - Analyzer status AS-i Circuit 2
Read only.
This object contains a bit pair for all 62 possible slaves which represents the sta-
tus of the slaves at this address:
11.4.3.2 Vendor Specific Object 7 – Device Colors OSSD 1
Read only.
This object contains all the devices associated with Release Circuit 1, the colors
as well as additional information for all release circuits.
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1 3/3A3/3A2/2A2/2A1/1A1/1A– –
2 7/7A7/7A6/6A6/6A5/5A5/5A4/4A4/4A
……
16 31B 31B 30B 30B 29B 29B 28B 28B
Tab. 11-12.
Bit Lamp color
11 red
10 yellow
01 green
00 no slave
Tab. 11-13.
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1 3/3A3/3A2/2A2/2A1/1A1/1A– –
2 7/7A7/7A6/6A6/6A5/5A5/5A4/4A4/4A
……
16 31B 31B 30B 30B 29B 29B 28B 28B
Tab. 11-14.
Information!
If not all 255 devices are used, the Monitor can shorten the S-7.5.5 telegram to save