Electrical connection
7.4.4 Electrical connection 103302
7.5 Diagnostics interface
The service and diagnostics interface (in conjunction with AS-i Control Tools or
ASIMON 3 G2 software) is used for communication between the PC and the unit.
7.5.1 103374, 103302, 103373, 103267
The service and diagnostics interface in these devices is configured as a mini
DIN-6 female and it is placed on the front plate, on the left hand side.
M4
5 mm max!
+
-
+
-
+
-
+ASI 1–
+ASI
1–
+
Gateway Safety Monitor
+ASI 2–
ASI +PWR– (max. 8 A)
Function ground
Terminal Signal / Description
+ASI 1– Connection to AS-i Circuit 1
+AS-i 2– Connection to AS-i Circuit 2
ASI +PWR– Supply voltage for AS-i Circuits (max. 8 A)
FG Function ground
Information!
AS-i Circuit 1 and 2 are both powered from a
Euchner GmbH + Co. KG power sup-
ply!
No other power supplies are approved!
Information!
For additional information, please refer to the section <AS-i and power supply terminal
assignments>.