Safety Monitor for 2 AS-i circuits Instruction Manual

172
Subject to reasonable modifications due to technical advances Id.-No.: 103329 Issue date - 24.10.2008 EUCHNER GmbH + Co. KG
Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen Tel. +49/711/75 97-0 • Fax. +49/711/753316
AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor
Appendix: example of a bidirectional safety coupling
18. Appendix: example of a bidirectional safety coupling
The following example describes a biderectional safety coupling between 2 AS-i
circuits.
Couple slave A
Couple slave B
AS-i circuit 1, OSSD 1
AS-i circuit 1, OSSD 2
AS-i circuit 2, OSSD 1
AS-i circuit 1:
OSSD 1: All EMERGENCY STOPs in circuit 1.
OSSD 2: Alle other safety objects + couple slave B.
AS-i circuit 2:
OSSD 1: All EMERGENCY STOPs in circuit 2 + couple slave A