Safety Monitor for 2 AS-i circuits Instruction Manual

12
Subject to reasonable modifications due to technical advances Id.-No.: 103329 Issue date - 24.10.2008 EUCHNER GmbH + Co. KG
Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen Tel. +49/711/75 97-0 • Fax. +49/711/753316
AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor
General
2. General
2.1 Product information
This system manual applies to the following Euchner GmbH + Co. KG equipment:
The AS-i/Gateway with integrated Safety Monitor combines an AS-i 3.0 PROFI-
BUS Gateway with a Safety Monitor for 2 AS-i circuits. The product offers the full
functionality of an AS-i/PROFIBUS Gateway and an AS-i Safety Monitor for 2
AS-i circuits.
The safety unit provides 4 inputs which can be defined as either EDM or as
START inputs.
The AS-i PROFIBUS gateways are designed to connect AS-i systems to an up-
per-level PROFIBUS network. The gateways act as a master for AS-i and as a
slave on PROFIBUS.
AS-i 3.0 PROFIBUS Gateway single master with inte-
grated safety monitor for 2 AS-i circuits
(1 master, RS 232 diagnostic interface)
103373
AS-i 3.0 PROFIBUS Gateway single master with inte-
grated safety monitor/decoupling coil for 2 AS-i circuits
(1 master, RS 232 diagnostic interface)
103267
AS-i 3.0 PROFIBUS Gateway with integrated safety
monitor for 2 AS-i circuits
(double master, RS 232 diagnostic interface
103374
AS-i 3.0 PROFIBUS Gateway with integrated safety
monitor for 2 AS-i circuits
(double master in version "1 power supply, 1 gateway for
2 AS-i circuits", RS 232 diagnostic interface)
103302
Tab. 2-1.
Functions of the device
1 master
2 master
OSSDs
AS-i
Master, power supply
Diagnostic interface
Semiconductor outputs
SaW outputs
Safety relays
103373 16 2 1 RS 232 2 16 2
103267 16 2 1N RS 232 2 16 2
103374 16 2 2 RS 232 2 16 2
103302 16 2 2N RS 232 2 16 2
Tab. 2-2.