Operating Instructions
33
MAN20001512-01-03/22 (translation of the original operating instructions)
Operating Instructions
Key Adapter CKS2-K-BP/BR-CC-FLX
EN
14.4. Acknowledging error messages
Depending on the error type, the error message can be acknowledged by briey removing the key or by a reset.
The reset can be performed as follows.
Reset
Centrally for
all devices in a
chain
Each device
must be ad-
dressed indi-
vidually
Further information
By briey disconnecting the power supply - -
Via the cyclical data of IO-Link communication - See operating instructions for the IO-Link Gateway
Via the acyclical data of IO-Link communication -
See chapter 11.3.2. Acyclical data (device data and events) on
page 25
Resetting to acknowledge error messages does not delete the conguration.
Important!
Contact the manufacturer if the fault display is not reset after briey disconnecting the power supply.