Operating Instructions

Operating Instructions
Key Adapter CKS2-K-BP/BR-CC-FLX
32
(translation of the original operating instructions) MAN20001512-01-03/22
Error code via IO-Link
LED indicator Error Troubleshooting
Acknowledg-
ing errors
Remove key for 2s
Reset
Output error
0x4C
0x4D
violet quickly
A short circuit or ground fault is detected at safety
output FO1A or FO1B during the self-test.
Check wiring.
0x54
A short circuit or ground fault is detected at safety
output FO1A or FO1B during operation.
Environment error
0x60
¨
orange/red
slowly
Supply voltage too high Decrease supply voltage.
0x61
Supply voltage too low Ì Increase supply voltage.
Ì Check system conguration: cable length, number of
devices in the switch chain.
0x62
¨
orange/red
quickly
Device temperature too high.
Ì Observe the specied temperature range, see chapter
15. Technical data on page 34
0x63
Device temperature too low.
Internal error
0x01
red
In case of series connection with IO-Link communication:
Safety input FI1A is routed to safety output FO1B of the
previous device.
Check wiring.
Ì Internal device error
Ì Supply voltage extremely high or extremely low.
Ì Device temperature extremely high or extremely low.
Ì Check supply voltage.
Ì Check device temperature.
Ì Restart the device. On repeated occurrence, contact
the manufacturer.