Operating Instructions
Operating Instructions
Key Adapter CKS2-K-BP/BR-CC-FLX
30
(translation of the original operating instructions) MAN20001512-01-03/22
14.2. Status messages
Operating
mode
LED indicator
Safety out-
puts FO1A /
FO1B
Monitoring
output
signal OD
Status
Self-test
white quickly
3Hz
(only for CKS2-BR: 5 s)
off off
Self-test after operating voltage is switched on.
green quickly
No communication with the BR/IO-Link Gateway.
Normal operation
green slowly
off off Device is ready for operation. No key inserted.
green
on on
Key inserted. The safety outputs of the preceding device in a series connection are switched
on.
¨
green/orange
slowly
off on
Key inserted. The safety outputs of the preceding device in a series connection are switched
off.
Teach-in operation
white
off
off Device is in teach-in standby (see chapter 12.2. Teaching-in a new key on page 27).
¨
white/violet
slowly
on Teach-in operation
¨
green/blue
quickly
off Positive acknowledgment after successful teach-in operation.
Factory
reset
¨
white/blue
quickly
off off Factory reset
Error
depending on the error off
depending on
the error
Error message (see chapter 14.3. Error messages on page 31)