12.3. Electrical function test
WARNING
Danger of fatal injury as a result of faults in installation and functional check.
Ì Before carrying out the functional check, make sure that there are no persons in the danger zone.
Ì Observe the valid accident prevention regulations.
After installation and any fault, the safety function must be fully checked. Proceed as follows:
1. Switch on operating voltage.
¨ The machine must not start automatically.
¨ The key adapter carries out a self-test. The LED then ashes green slowly.
2. Insert key.
¨ The LED illuminates green.
3. Enable operation in the control system.
4. Remove key.
¨ The machine must switch off and it must not be possible to start it as long as a key is not inserted.
¨ The LED ashes green slowly.
Repeat steps 2…4 for each key adapter.
13. Factory reset
A factory reset deletes the conguration and restores the device’s factory settings.
To perform a factory reset, connect the two outputs FO1A and FO1B to 0 V before switching on or send the command Ox1E
via IO-Link communication (see chapter 11.3.2. Acyclical data (device data and events) on page 25).