Operating Instructions

13
MAN20001512-01-03/22 (translation of the original operating instructions)
Operating Instructions
Key Adapter CKS2-K-BP/BR-CC-FLX
EN
8.4. Requirements for connecting cables
CAUTION
Risk of damage to equipment or malfunctions as a result of incorrect connecting cables.
Ì Use connection components and connecting cables from EUCHNER.
Ì On the use of other connection components, the requirements in the following table apply. EUCHNER
provides no warranty for safe function in case of failure to comply with these requirements.
Observe the following requirements with respect to the connecting cables:
Parameter Value Unit
Conductor cross-section, min. 0.25 … 0.34 mm²
R max. 80 W/km
C max. 120 nF/km
L max. 0.65 mH/km
Recommended cable type
5-pin 5 x 0.34mm²
8-pin LIYY 8 x 0.34mm²
8.5. Connector assignment of key adapter CKS2-K-BR-CC-FLX-F00-USA-…
with plug connector M12, 8-pin
Plug connector
(view of connection side)
Pin Designation Function
Conductor coloring
of connecting
cable
1)
21
4
3
8
5
6
7
1 FI1B Enable input, channelB WH
2 UB Operating voltage, 24VDC BN
3 FO1A Safety output, channelA GN
4 FO1B Safety output, channelB YE
5 OD/C Monitoring output/communication GY
6 FI1A Enable input, channelA PK
7 0V Ground 0VDC BU
8 - n.c. RD
1) Only for standard EUCHNERconnecting cable
8.6. Connector assignment of key adapter CKS2-K-BP-CC-FLX-F00-USI-…
with plug connector M12, 5-pin
Plug connector
(view of connection side)
Pin Designation Function
Conductor coloring
of connecting
cable
1)
1
4
3
2
5
1 UB Operating voltage, 24VDC BN
2 FO1A Safety output, channelA WH
3 0V Ground 0VDC BU
4 FO1B Safety output, channelB BK
5 - n.c. GY
1) Only for standard EUCHNERconnecting cable