Operating Instructions

29
2112657-15-06/20 (translation of the original operating instructions)
Operating Instructions Safety Systems
MGB-L0…-AR.-… and MGB-L0…-AP.-…
EN
13. Technical data
NOTICE
If a product data sheet is included with the product, the information on the data sheet applies in case
of discrepancies with the operating instructions.
Parameter Value Unit
Housing material Fiber glass reinforced plastic
die-cast zinc, nickel-plated
stainless steel
Dimensions See chapter 7.4. Dimension drawing on page 10
Weight
Interlocking module
Handle module
Escape release
0.75
1.00
0.50
kg
Ambient temperature at U
B
= DC24V -20 … +55 °C
Degree of protection
Cover not populated/populated with buttons/indi-
cators/selector switches
Cover populated with key-operated switch
Cover populated with key-operated rotary switch FS22
IP65
IP 54
IP 42
Safety class III
Degree of contamination 3
Installation position Any
Connection 4 cable entries M20x1.5 or plug connector
Conductor cross-section (rigid/exible)
- With ferrule according to DIN46228/1
- With ferrule with collar according to DIN46228/1
0.13 … 1.5 (AWG 24 … AWG 16)
0.25 … 1.5
0.25 … 0.75
mm²
Operating voltage UB
(reverse polarity protected, regulated, residual
ripple <5%)
24 +10% / -15% (PELV) V DC
Auxiliary voltage UA
(reverse polarity protected, regulated, residual
ripple <5%)
24 +10% / -15% (PELV) V DC
Current consumption I
UB
(no load on any outputs) 80 mA
Current consumption I
UA
- Pushbutton S (unloaded, per LED) 5
mA
External fuse See chapter 11.3. Fuse protection for power supply on page 19
Safety outputs FO1A/FO1B Semiconductor outputs, p-switching, short circuit-proof
Test pulses AR <1,000/AP <300 µs
Test-pulse interval Min. 100 ms
Output voltage U
FO1A
/ U
FO1B
1)
HIGH U
FO1A
/ U
FO1B
U
B
-2V … U
B
LOW U
FO1A
/ U
FO1B
0 … 1 V DC
Switching current per safety output 1 … 200 mA
Utilization category according to ENIEC60947-5-2 DC-13 24 V 200 mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.
Monitoring outputs
- Output voltage
1)
- Max. load
p-switching, short circuit-proof
U
A
- 2V … U
A
Max. 50 mA
Rated insulation voltage U
i
30 V
Rated impulse withstand voltage U
imp
1.5 kV
Resilience to vibration Acc. to ENIEC60947-5-3
Switching frequency 0.25 Hz
EMC protection requirements Acc. to ENIEC60947-5-3
Reliability values acc. to ENISO13849-1
Category 4
Performance Level PL e
PFH
D
3.7 x 10
-9
/ h
2)
Mission time 20 years
Mechanical life 1x10
6
- In case of use as door stop, and 1 Joule impact
energy
0.1x10
6
B
10D
(emergency stop) 0.065x10
6
Emergency stop
Operating voltage 5 … 24 V
Operating current 1 … 100 mA
Breaking capacity max. 250 mW
Power supply LED 24 V DC
Controls and indicators
Operating voltage UA V
Operating current 1 … 10 mA
Breaking capacity max. 250 mW
Power supply LED 24 V DC
1) Values at a switching current of 50 mA without taking into account the cable length.
2) Applying the limit value from ENISO13849-1:2008, section 4.5.2 (MTTFd = max. 100 years), the employers’ liability insurance association certies a PFHd of max. 2.47 x 10
-8
.