7.2. Emergency unlocking
Permits opening of a locked guard from outside the danger zone without tools. For mounting, see the mounting supplement.
Important!
Ì It must be possible to operate the emergency unlocking manually from outside the protected area
without tools.
Ì The emergency unlocking must possess a marking indicating that it may be used only in an emer-
gency.
Ì The actuator must not be under tensile stress during manual release.
Ì The emergency unlocking must be sealed or the misuse of the release function must be prevented
in the control system.
Ì The unlocking function meets all other requirements from ENISO14119.
Ì The emergency unlocking meets the requirements of Category B according to
ENISO13849-1:2015.
Ì Loss of the release function due to mounting errors or damage during mounting.
Ì Check the release function every time after mounting.
Ì Please observe the notes on any enclosed data sheets.
7.2.1. Actuating emergency unlocking
Ì Turn emergency unlocking clockwise until it clicks into place.
¨ Guard locking is released.
To reset, press the snap-in bolt inward using a small screwdriver or similar tool and turn the
emergency unlocking back.
The safety outputs are switched off when the emergency unlocking is actuated. Use the safety
outputs to generate a stop command.
The monitoring output OL is switched off; OD can assume an undened state. Open the guard and
close it again after resetting the emergency unlocking. The device will then operate normally again.
7.3. Escape release (optional)
Permits opening of a locked guard from the danger zone without tools (see chapter 13.3. Dimension
drawing for safety switch CTP… on page 36).
Important!
Ì It must be possible to actuate the escape release manually from in-
side the protected area without tools.
Ì It must not be possible to reach the escape release from the outside.
Ì The actuator must not be under tensile stress during manual release.
Ì The escape release meets the requirements of Category B according
to ENISO13849-1:2015.
7.3.1. Actuating escape release
Ì Press the red release knob to the end stop
¨ Guard locking is released.
Pull the knob out again to reset.
The safety outputs are switched off when the escape release is actuated. Use the safety outputs to generate a stop
command.
The monitoring output OL is switched off; OD can assume an undened state. Open the guard and close it again after re-
setting the escape release. The device will then operate normally again.
Snap-in bolt