System Manual

Table Of Contents
Manual EKS Electronic-Key Adapter Ethernet TCP/IP
2100420-03-05/19 Subject to technical modifications Page 31/34
8.4 Command overview
Description
Command message
Reply message
Program Electronic-Key
TP (see chapter 8.3.1)
RF (see chapter 8.3.1)
Read Electronic-Key
(also read the serial number)
TL (see chapters 8.3.2 and 8.3.3)
RL (see chapter 8.3.2)
or
RF (see chapter 8.3.2)
Read the Electronic-Key status
Ek (see chapter 8.3.4)
Ek (see chapter 8.3.4)
8.5 Status numbers
Value
Description
00
hex
No error
02
hex
Electronic-Key not in the operating distance
03
hex
Parity bit error on read-only Electronic-Key
06
hex
Write process interrupted. Start address or number of bytes is not a multiple of the block size 4
17
hex
Read attempt when the Electronic-Key adapter is set to read/write Electronic-Key and a read-only
Electronic-Key is inserted
18
hex
Read attempt when the Electronic-Key adapter is set to read-only Electronic-Key and a read/write
Electronic-Key is inserted
4x
hex
General Electronic-Key communication error (renewed write or read process necessary)
50
hex
Write attempt despite enabled write protection
61
hex
Maximum permissible number of TCP/IP connections exceeded