innovative technology ITNS-400 User Manual
I. Unpack the ITNS-400 User Manual ITNS-400 Quick Installation Guide Note This film scanner supports Windows XP, Vista/Windows7 (32/64bits) via USB 2.0 only. We strongly suggest using a clean, dry, non-alcohol cotton swab to insert into the film scanner slot and clean the glass surface periodically to produce a clear image. Make sure all negative films, slide films, and cover trays are free of dust and dirt before inserting into the ITNS-400 as this may affect the image quality when scanning.
II. Driver Installation To use the ITNS-400, please complete the following installation in advance. 1. Turn on the computer 2. Insert the installation CD into the CD-ROM drive and the installation CD menu will appear. 3. Choose Installation.
. Follow the on-screen instructions.
-4-
-5-
-6-
5. After completing software installation, please connect ITNS-400 to PC. The New Hardware Wizard will detect a new device.
6. Select “Yes” in XP or “Locate and install driver software (recommended)” in Vista/Windows7 OS.
7. After completing the installation, the filmscanner is ready to start with “35mm FilmScanner” Image Scan Tool under program files. (Windows XP, Vista/Windows7) Restart is not required, but it is recommended to restart your PC after installation/un-installation. III.
Installing film into the film holder Install slide Film into the holder entitled “Slides Only” 1. Open the slide holder as illustrated 2. Place slide in recessed slot in holder 3. Close the film holder Install Negative Film into the holder entitled “Negative Film Only”: 1. Open the film holder as illustrated 2. Install film into negative film slot 3.
Note To avoid a mirror image, follow the serial numbers (from left to right) on top of film when installing negative film into holder. Figure 1 If the image is upside down [see fig.2], the image can be corrected by “Rotate” function in Image Scan Tool after capture [see fig.3].
How to use ITNS-400 1. Put Film into film holder 2.
3. Connect ITNS-400 to PC 4.
5. Press “Copy” button to capture the image 6.
7. Save captured images to PC 8.
User interface introduction When user selects a “Negative” source, the image in “Live View” window will be exactly like the processed result.
If device processes a slide, the “Live View” will show a color image and the FilmType will remain the same. This is the live view under black and white negative option.
User can convert images from traditional film to digital either by “Snap Shot” button in Image Scan Tool or the button on top of filmscanner. Then, the capture result will appear in the “Snap Shot” and “Final images to save” window. Touch button All of the effects in Image Scan Tool will be ready for instant preview in “Snap Shot” and “Final images to save” window.
Apply the Mirror function by pressing the “Mirror” icon, that will flip the image and be shown in the “Snap Shot” window as well as the “Final images to Save”. Or apply the Rotate function by pressing “Rotate” button, the image will be rotated 90 degrees each time. Images can be continuously rotated a full 360 degrees or until desired.
If the user wishes to delete a specific image from the capture pool, simply click the image under “Final image to save” again, then the selected image can be deleted by applying the “Delete” button. After modification, user can save images to the default location at “C:\Documents and Settings\Users\My Documents\My Pictures”.
Or define preferable location for saving captures images by pressing the directory button. Another window will pop out for user to select required location. Once press “Save” key, all of captures images will be saved into defined location. The “final image” saving window shall be empty after press the “Save” button.
When the capture is complete, the user can press “Exit” button to quit this Image Scan Tool, Then, review captured images or process more fancy modification with bundle software for PC.
IV. Specification Image Sensor: Lens: 5 mega CMOS sensor F no.=2.0, 4 Glass elements, Focus Range: Exposure Control: Color Balance Scan Quality Data Conversion Scan Method Light Source Interface: Power: Dimensions Fixed focus Automatic Automatic 1,800 dpi /3600 dpi (SW interpolation) 10 bits per color channel Single pass Back light (3 white LEDs) USB 2.0 USB port W100.6 x L90.5 x H150.3mm Weight Operating Systems 0.
V. Cleaning the ITNS-400 Please remove the film holder from device when you notice any dust in the live view window. Then you can use the cleaning brush to wipe away dust. Note We strongly suggest using a clean, dry, non-alcohol cotton swab to clean the glass surface periodically to produce a clear image during operation.
ITNS-400 Trouble shooting Question 1. How to install ITNS‐400 driver? : Solution: 01. Put FilmScan Driver CD‐ROM into your CD player. 02. Open the X(CD‐ROM):\Driver\folder. 03. Click mouse right buttonon setup.exe, and click “Run as administrator” to install driver. 04.The InstallShield Wizard will show the message of “InstallShield Wizard Completed once the driver installed ready. 05.Connect ITNS-400 to your PC, the PC will complete the device driver installation and confirm driver installed successfully.
Question 2. Came up the error message “Cannot Install This Hardware” or “ Can not find camera.
Solution: 01.Check your USB cable to make sure it is well connected to your PC and your device. 02.Check your PC to verify the driver is installed properly. 03. Uninstall the existing driver from your system. a. Using the uninstall program of ITNS‐400 application Run start→All programs (Vista/Win7) or Program files (XP)→35mm film scanner→35mm film scanner →Uninstall 35mm Film Scanner b. or Using the tool in device manager (1) Open Device Manager.
Windows Vista Open Start →Control Panel→System →Device Manager Wondows 7 Open Start → Control Panel → System and Security → System → Device Manager (2) Click the right button of mouse from “Unknown device” and uninstall the driver. 04. Re‐install proper driver version again.
Question 3. If you can’t uninstall the driver or came up the error message “ Can’t find the device, you may plug‐in the device and try again.” or “Failed to uninstall the device. The device may be required to boot up the computer.” Solution: Please refer to Question 2 solution and reboot your computer, if it still can’t work, please contact us through e-mail support@ithomeproducts.com Question 4.
Question 5. You can’ t see the pre‐view image from ITNS‐400 application when you have re‐installed driver and device status is completed. Reason: Devices confliction. (Such as USB cameras or devices.
Solution: 01. Disable the other imaging devices by using bundled program in standard package first or disable it by the option under Imaging device when press right button of mouse. 02. Re‐start ITNS‐400 application again. Question 6. Come up the error message “General failure in transfer bad info header info. Bad value error”. OK Reason: Plug device into USB1.1 port. Solution: ITNS‐400 only supports USB 2.0. Please verify if your PC is compatible with USB2.0.
01 Open Device Manager. Windows XP Open Start →Setting→Control Panel→System→Hardware→Device Manager Windows Vista Open Start→Control Panel→System→Device Manager Windows 7 Open Start→Control Panel→System and Security→System→Device Manager 02 Your computer must with a USB 2.0 Controller in Universal Serial Bus controllers. The figure below shows the difference between USB1.1 and 2.0. There must be a “USB2” for USB 2.0 controller.
InnovativeTechnologyElectronicsCorp. LimitedWarranty 90DaysLabor, OneYearParts Innovative Technology Electronics Corp. (IT) warrants the product to be free from “ Defects” in materials under normal use for a period of “ One Year”fom the date of the orginal purchase. The Warrantyis “Not”transferable. ITagrees, withintheinitial “90Day”period, torepairtheproductif itisdeterminedtobedefectiveat “NoCharge”.
Instructions shall caution users that modifications not approved by the party responsible for compliance could void user's authority to operate the equipment. The following or equivalent as appropriate: “NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Driver Revision: 1.