Final draft ETSI EN 300 328 V1.8.1 (2012
-
04)
60
• Trace Mode: Max Hold
Step 2:
In case of conducted measurements on smart antenna systems (equipment with multiple receive chains), the step 1
needs to be repeated for each of the active receive chains (A
ch
).
The trace data for each receive chain has to be recorded.
Sum the power in each of the traces for each individual frequency bin.
Step 3:
Use the marker function to find the highest peak within the measurement trace and record its value and its frequency.
Step 4:
The measured values shall be compared to the limits defined in tables 2 and 5.
5.3.11.2.2 Radiated measurement
The test site as described in annex B and applicable measurement procedures as described in annex C shall be used.
The test procedure is further as described under clause 5.3.11.2.1.