Specifications

ETSI
Final draft ETSI EN 300 328 V1.8.1 (2012
-
04)
54
Step 1:
Connect the UUT to the spectrum analyser and use the following settings:
- Centre Frequency: 2 484 MHz
- Span: 0 Hz
- Resolution BW: 1 MHz
- Filter mode: Channel filter
- Video BW: 3 MHz
- Detector Mode: RMS
- Trace Mode: Clear / Write
- Sweep Mode: Continuous
- Sweep Points: 5 000
- Trigger Mode: Video trigger
NOTE 1: In case video triggering is not possible, an external trigger source may be used.
- Sweep Time: Suitable to capture one transmission burst
Step 2: (segment 2 483,5 MHz to 2 483,5 MHz + BW)
Adjust the trigger level to select the transmissions with the highest power level.
For frequency hopping equipment operating in a normal hopping mode, the different hops will result in signal
bursts with different power levels. In this case the burst with the highest power level shall be selected.
Set a window (start and stop lines) to match with the start and end of the burst and in which the RMS power
shall be measured using the Time Domain Power function.
Select RMS power to be measured within the selected window and note the result which is the RMS power
within this 1 MHz segment (2 483,5 MHz to 2 484,5 MHz). Compare this value with the applicable limit
provided by the mask.
Increase the centre frequency in steps of 1 MHz and repeat this measurement for every 1 MHz segment within
the range 2 483,5 MHz to 2 483,5 MHz + BW. The centre frequency of the last 1 MHz segment shall be set to
2 483,5 MHz + BW - 0,5 MHz (which means this may partly overlap with the previous 1 MHz segment).
Step 3: (segment 2 483,5 MHz + BW to 2 483,5 MHz + 2BW)
Change the centre frequency of the analyser to 2 484 MHz + BW and perform the measurement for the first
1 MHz segment within range 2 483,5 MHz + BW to 2 483,5 MHz + 2BW. Increase the centre frequency in
1 MHz steps and repeat the measurements to cover this whole range. The centre frequency of the last 1 MHz
segment shall be set to 2 483,5 MHz + 2 BW - 0,5 MHz.
Step 4: (segment 2 400 MHz - BW to 2 400 MHz)
Change the centre frequency of the analyser to 2 399,5 MHz and perform the measurement for the first 1 MHz
segment within range 2 400 MHz - BW to 2 400 MHz Reduce the centre frequency in 1 MHz steps and repeat
the measurements to cover this whole range. The centre frequency of the last 1 MHz segment shall be set to
2 400 MHz - 2BW + 0,5 MHz.
Step 5: (segment 2 400 MHz - 2BW to 2 400 MHz - BW)
Change the centre frequency of the analyser to 2 399,5 MHz - BW and perform the measurement for the first
1 MHz segment within range 2 400 MHz - 2BW to 2 400 MHz - BW. Reduce the centre frequency in 1 MHz
steps and repeat the measurements to cover this whole range. The centre frequency of the last 1 MHz segment
shall be set to 2 400 MHz - 2BW + 0,5 MHz.