Specifications

ETSI
Final draft ETSI EN 300 328 V1.8.1 (2012
-
04)
49
NOTE 3: The verification of the Short Control Signalling transmissions may require the analyser settings to be
changed (e.g. sweep time).
iv) Alternatively, the equipment may switch to a non-adaptive mode.
Step 5: Adding the blocking signal
With the interfering signal present, a 100 % duty cycle CW signal is inserted as the blocking signal. The
frequency and the level are provided in table 6 of clause 4.3.2.10.2.
Repeat step 4 to verify that the UUT does not resume any normal transmissions.
Step 6: Removing the interference and blocking signal
On removal of the interference and blocking signal the UUT is allowed to start transmissions again on this
channel however, it shall be verified that this shall only be done after the period defined in clause 4.3.2.5.1.2
step 2.
Step 7:
The steps 2 to 6 shall be repeated for each of the frequencies to be tested.
5.3.7.2.1.3 LBT based adaptive equipment using modulations other than FHSS
The different steps below define the procedure to verify the efficiency of the LBT based adaptive mechanism of
equipment using wide band modulations other than FHSS. This method can be applied on Load Based Equipment and
Frame Based Equipment.
Step 1:
The UUT may connect to a companion device during the test. The interference signal generator, the blocking
signal generator, the spectrum analyser, the UUT and the companion device are connected using a set-up
equivalent to the example given by figure 5 although the interference and blocking signal generator do not
generate any signals at this point in time. The spectrum analyser is used to monitor the transmissions of the
UUT in response to the interfering and the blocking signals.
Adjust the received signal level (wanted signal from the companion device) at the UUT to the value defined in
table 6 (clause 4).
NOTE 1: Testing of Unidirectional equipment does not require a link to be established with a companion device.
The analyzer shall be set as follows:
- RBW:
Occupied Channel Bandwidth (if the analyser does not support this setting, the
highest available setting shall be used)
- VBW: 3 × RBW (if the analyser does not support this setting, the highest available setting
shall be used)
- Detector Mode: RMS
- Centre Frequency: Equal to the centre frequency of the operating channel
- Span: 0 Hz
- Sweep time: > maximum Channel Occupancy Time
- Trace Mode: Clear Write
- Trigger Mode: Video
Step 2:
Configure the UUT for normal transmissions with a sufficiently high payload to allow demonstration of
compliance of the adaptive mechanism on the channel being tested.