Operation Manual

46 - Epic 442 Assembly and User Manual
4930659-02
Parameters
Parameters are settings within the timer soft-
ware which allow changes to the way the
tanning bed operates. Your tanning bed must
be disconnected from any external timers to
access these parameters from the timer dis-
play handle.
1. With the bed idle (display showing “0”),
press the STOP button and, without re-
leasing it, press the START/TIME but-
ton. The display will change to “PRAM”
briey, then “P 1” to signify parameter
1, then the parameter value.
2. Use the ‘+’ and/or ‘-’ buttons to change
the parameter value.
3. Press the START/TIME button to advance
to the next parameter.
4. Press STOP to return to idle.
The next page shows the parameters that
can be changed by the salon owner. Refrain
from changing any parameters not listed as
bed function may be adversely affected.
To reset the bed to factory defaults, set the
Bed Address (P 1) to 255, exit parameter
mode and cycle power to the bed.
Updating Timer Software
Hanging on the foot end of the bed (next
to the body fan) is a cable with a USB ash
drive. This ash drive contains a single le
which is the timer software. During normal
use the ash drive may be removed as it
does not interface with the timer. However,
if ETS releases a new software update, you
can easily update the timer.
Be sure to keep the ash drive with the bed.
It contains one le and must not be used
for any other purposes. Updates will be
emailed to you to copy onto this drive from
any computer, but it must be the only le on
the drive to work properly.
Updating the timer software:
1. With the bed idle (display showing “0”),
press and hold the STOP button until the
display changes from “0” to “Id”.
2. Within 5 seconds, press the FAN button
and the display will show “PGM?” indi-
cating it is ready to program the timer.
3. Press the START/TIME button to begin
programming the bed. The display will
show “WAIT”.
4. After the update is complete, the timer
will reset and the bed will be ready to go
once the timer display reads “0”.
In the event you receive an email contain-
ing an update le, the email will contain full
instructions on this procedure as well as the
verication process to make sure the update
was successful.