Service manual
Page 67 of 151
• Remove the ramp plate.
• Remove weight rollers from movable drive face.
Inspection
• The weight rollers press the movable drive face
by centrifugal force.
• If the weight rollers are worn out or damaged,
the force will be affected.
• Check if rollers are worn or damaged. Replace
if necessary.
• Measure each roller’s outer diameter. Replace it
if it exceeds the service limit.
• Service limit: mm (Weight: 18.2g)
• Check if drive face boss is worn or damaged and
replace it if necessary.
• Measure the outer diameter of movable drive face
boss, and replace it if it exceeds service limit.
• Service limit: mm
• Measure the inner diameter of movable drive face,
and replace it if it exceeds service limit.
• Service limit: mm
Copyright ©2008-2009 ETON America, llc., all rights reserved.
www.Get2itParts.com
www.Get2itParts.com
www.Get2itParts.com