5-5 Air Cut-Off Valve
Disassembly
• Remove the two screws to gain access to
the air cut-off valve.
• Remove the air cut-off valve cover,
spring, and valve.
Inspection
• Check the valve for damage or wear.
• If the valve is undamaged, it will restrict air
flow.
• If air flow is not being restricted, install a
new carburetor kit.
• Ensure the vacuum pipe O-ring is
undamaged and can be reused.
Assembly
• Install in reverse order of removal.