Service manual
ETON America, LLC
C.D.I. Module Specifications
Vector 250
Service Bulletin
Specifications highlighted in yellow are the suggested critical testing points. Test points should be
tested first.
We suggest using analogy type multi-meter to test the electric resistance. We have found using
digital type meter produces to many inaccurate readings.
VXL-250 -- C0410-LRA0-0000
Electric resistance(Ω) specification
ACC
PC+ PC- IGN BACK GND
ACC
50-70K 1-2K ∞ 20-30K 4.8-5.2K
PC+
∞
30-50K ∞ 80-100K 30-50K
PC-
∞ 30-50K
∞ 7-8K 0
IGN
∞ 50-60K 1-3K
13-15K 1-3K
BACK
∞ ∞ ∞ ∞
∞
GND ∞ 30-40K 0 ∞ 7-8K
Bulletin No.:
SB-0037