11-5 Crankshaft Inspection
Use a thickness gauge to measure the left and
right clearance of the larger end of the
connecting rod.
Service limit: 0.6 mm
Measure the clearance of the larger end in the
vertical direction.
Service limit: 0.05 mm
Place the crankshaft on a V-block.
Measure the run-out of the crankshaft.
Service limit: 0.10 mm
Crankshaft Bearing Inspection
Use your hand to turn the bearing.
It should turn smoothly and quietly.
Check the inner ring to ensure it links firmly on
the bearing.
If any roughness, noise, or loose linkage is
detected, replace the bearing.
Note: If bearing replacement is necessary,
replace both bearings.
Special tool: Outer bearing puller