Installation Guide
On and Blinks
Off approx every
20 seconds
Silent Off and Blinks
On approx every
40 seconds
Off Off
1 beep,
1 second
pause,
4 beeps
Blinks in
sync with
cycle of the
first beep
Blinks in
sync with
cycle of
4 beeps
Horn sounds
when no
hazard is
present
On and blinks
Off approx
every 20
seconds
Blinks when
no hazard is
present
Blinks when
no hazard
is present
Condition: Nuisance Alarm.
Recommendation: If there is no hazard present, verify the
alarm is mounted in the correct location (see User's
Manual, "AVOID THESE LOCATIONS" section). Reset
alarm as instructed below.
4 beeps,
5 second
pause,
repeat
Off
Condition: CO alarm when cause of alarm is known and
poses no threat.
Recommendation: The CO Alarm Silence Feature is
activated by pressing and releasing the TEST/CO
SILENCE button on the initiating alarm while in alarm
condition. The alarm will remain silent for approx 5
minutes, depending on the level of CO detected. If CO
levels drop below alarm levels, the alarm will remain silent
and return to normal operation. If CO levels remain
constant or increase, this indicates potentially dangerous
situation and the horn will sound again. Ventilate area.
Blinks in
sync with
cycle of
4 beeps
Off Off
POWER
GREEN LED
CO
RED LED
AUDIBLE & VISUAL SIGNALS
Silent
GAS
BLUE LED
HORN
OPERATIONAL SUMMARY
Condition: Latching CO LED Indicator. The alarm has
previously detected CO and had alarmed.
Recommendation: Follow the reset instructions to remove
the latching LED.
Off and
blinks On
approx every
5 seconds
until reset
Silent
Off
Condition: Latching Gas LED Indicator. The alarm has
previously detected Gas and alarmed.
Recommendation: Follow the reset instructions to remove
the latching LED.
Off and
blinks On
approx every
5 seconds
until reset
ffOtneliS
CONDITION / RECOMMENDATION
4 beeps,
5 second
pause,
repeat
Blinks Off when
the Red LED
blinks On
Off
Blinks in
sync with
cycle of
4 beeps
Condition: CO alarm
Recommendation: If a hazard is identified, please take
all precautions when an alarm sounds by calling an
Emergency Service and getting out of the home.
1 beep,
1 second
pause,
repeat
ffOwoleb eeS *
Blinks in
sync with
cycle of the
first beep
Condition: Gas alarm.
Recommendation: If a hazard is identified, please take
all precautions when an alarm sounds by calling an
Emergency Service and getting out of the home.
* See below
* See below
* See below
Turns Off in
sync with
cycle of the
first beep
Condition: AC Power is present. DC power is present.
Recommendation: None, alarm is operating properly.
Condition: Alarm is powered by battery backup. AC Power
is not present.
Recommendation: Check the breaker or fuse box for power.
If the breaker or fuse box looks normal, call a licensed
electrician for assistance.
Condition: The TEST/CO SILENCE button has been
pressed and released. The test sequence lasts for
approximately 3 seconds after the button is released.
Recommendation: None.
'RZQORDGWKH(WRQ6PDUWDSSIURPWKH$SSOH$SS6WRUHRU*RRJOH3OD\6WRUH
2QFHWKHDSSLVRQ\RXUVPDUWSKRQHODXQFKWKHDSSDQGIROORZWKHLQVWUXFWLRQVWRSDLU\RXU
Blackout Buddy Connect Combo
7KHODWHVWKRZWRDQGPDUNHWLQJYLGHRVIURP(WRQFDQEHIRXQGDW
https://vimeo.com/etoncorp
For support or questions please contact: customer_support@etoncorp.com
Note: The Blackout Buddy Connect Combo only supports 2.4GHz WiFi networks, if you have
a dual-mode (2.4GHz & 5GHz) combination router please ensure that the 2.4GHz radio is
turned on and broadcasting. Consult your router’s user manual for more information.
WIFI CONNECTIVITY VIA THE ETON SMART APPLICATION FOR IOS OR ANDROID