Specifications

EATON Screw-In Cartridge Valves E-VLSC-MC001-E2 May 2015C-28.A
C
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Installation Data
Start-Up Procedure
Correctly wire the plug and,
before mounting it on the
valve solenoid, apply 24V
DC (18 to 36V limits) to the
“power input” terminals.
Check for correct plug
function by illumination/
non-illumination of the LED:
a. Apply less than 2 to 3
volts to the input terminal:
LED should not be
illuminated.
b. Increase voltage: the LED
should illuminate when
the voltage reaches 11V.
Do not exceed 30V
command signal.
c. Decrease voltage: the LED
should go off when the
voltage is less than 5V.
Switch off power supply and
command/input signal and
then install plug on solenoid.
Ensure that all seals are
fitted correctly and clamped
as the retaining screw is
tightened: this is essential in
providing IP67 protection.
Ensure that the hydraulic
system will not cause any
erratic movement of
actuators, then:
Switch on power
supply again.
Repeat LED/function
check as in 2.
An LED malfunction now
indicates a short circuit at
the load.
Successful completion of
these checks means that
the plug and load are ready
for use.
Spare Parts
The only spare part available is
the interface seal, part number
732100.
Ordering Procedure
Order plug by full model code,
and spare interface seals by
part number 732100.
.B