Specifications
EATON Screw-In Cartridge Valves E-VLSC-MC001-E2 May 2015C-18.A
C
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
1 2
Model Code/
Operating Data
Model Code
1
Adjustment Range
D - Proportional plug:
0-10 VDC with ramp
K - Proportional plug:
4-20 mA with ramp
EHH - AMP - 702 - * - R - P - * - 30
2
Cable Gland
1 - PG9
2 - M16
Operating Data
Mechanical
Housing PA6 glass-reinforced plastic
(conforming to UL-94HB). Color: gray
Mounting interface ISO 4400 (DIN 43650)
Cable clamp Pg9 screw type
Cable diameter Ø 5 to 10 mm (0.197 to 0.394” dia.)
Wire section 0,5 to 1,0 mm2 (20-17 AWG)
Temperature, ambient range -20° to +70°C (-4° to +158°F)
Mass 0,07 kg (0.154 lb)
Electrical
Types D Type K
Connections
1 24V DC
2 Supply GND
3 Positive command signal
4 Negative command signal
Power (input) supply 18-36V DC including ± 10% maximum ripple
(peak-to-peak)
24V DC nominal
Absolute maximum voltage 40V
Max. power consumption 35W
including solenoid
Reverse polarity protected Yes
Short circuit protected Yes
Maximum output current 1,6A
Maximum output voltage typical Typically 1,5V below supply voltage
(1,6A output current)
Command signal 0-10V (10 kohms) 4-20 mA (250 ohms)
Deadband triggering 200 mV 4 mA
For output (LED on) 200 mV to 10V 4-20 mA
For no output (LED off) 0 mV to 100 mV 0-4 mA
Deadband adjustment range 100 to 1000 mA
Gain adjustment range 0.02A/V to 0.16A/V 0.01 A/mA to 0.08 A/mA
Dither adjustment range 0 to 500 mA
Ramp time (types D and K only) 50 ms to 5s
PWM frequency 1200 Hz ± 10%
Dither frequency 120 Hz ± 10%
Protection IEC 529: IP67 (when correctly installed with
interface seal in place) Fully short-circuit and
reverse-polarity protected
Isolation to VDE 0110 Group “B”
Electromagnetic compatibility (EMC):
Emission EN 50081-2
Immunity EN 50082-2
.B