Specifications
EATON Screw-In Cartridge Valves E-VLSC-MC001-E2 May 2015 C-11.A
C
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
C13 and C16 Series -
Coil Information
Encapsulation Material
C13, 14 Watt coils and C16, 19 Watt coils are black in colour and
made from PBT (Black Polybutylene Reinforced) equivalent to Class F
(155°C)
C13, 22 & 27 Watt coils and C16, 29 Watt coils are black in colour and
made from IXEF (Black Polyarylamide Reinforced) equivalent to Class
H (180°C)
Ingress Protection (IP) BS EN 60529
The coil/tube joint is sealed by “O” rings preventing fluid ingress and
the possibility of tube corrosion.
Different electrical connectors offer different levels of protection
the minimum being the DIN 43650 connector with a gasket at IP65.
Integrated Hydraulics offer a wide range of connector types - details
of which are available on request.
Caution – When handling coils after or during use they may be hot
which can cause burning to the skin. Handle with care and use the
appropriate equipment.
Connectors
H = ISO4400 Standard DIN43650
2 pin and earth
F = Black Flying Leads 1.5mm
2
wire
600 mm long, 15 AWG, 2.2 mm diameter, Teflon FEP covered
(DC voltage only)
DM = Deutsch Moulded 2 way DT04-2P series
(DC voltage only).
Wattage
Wire Insulation
Voltages
Alternating Current
FPO
Copper Winding
Iron Frame/Yoke
Encapsulation
Electrical
Connection
Location of “O” ring seal
between coil and tube
Bobbin
+
-
DC Coil
C13 (for 13 mm tubes) = 14, 22 & 27 Watts
C16 (for 16 mm tubes) = 19 & 29 Watts
The coil winding is copper magnet wire insulation equivalent to
class N (200°C).
AC Voltage Connector Circuit Diagram
Standard
12 VDC 110 VRAC
24 VDC 220 VRAC
Special/Optional
Other Voltages are available on request
For AC voltage an ISO4400 rectified connector must be used,
as the coils are wound for DC. The correct connector is
available from the factory:
110 VAC = AXP9997-115
220 VAC = AXP9997-230
VDR is fitted for over-voltage protection.
Diodes are rated at 1.5 amp.
Duty Rating
The coil is rated for continuous operation at nominal voltage +/- 10%
and an ambient range of -20 to +40.
Note: Coil performance, force produced and power consumed, is
affected by the heat of the coil, performance figures given in this
catalogue are measured under simulated continuous duty conditions
at the coil stabilized temperature. It is important to verify the actual
conditions the valve will experience for any given application it should
be tested in situ to confirm valve selection.